Jet 7" polisher (gp712vs) ユーザーズマニュアル

ページ / 40
 
16
You can adjust any play of the miter gauge in 
the table slot by tightening set screws (E). 
Calibration 
If a miter angle at the -45º, 90º or +45º is not 
correct, the index stops can be adjusted by 
turning one of three adjustment screws (D), then 
locking the hex nut. 
Note: Always make test cuts. Do not rely solely 
on miter gauge indicator marks. 
9.0  Electrical connections 
The JPS-10TS table saw is rated at 115/230V 
power, and is pre-wired for 115 volt. The table 
saw comes with a plug designed for use on a 
circuit with a grounded outlet that looks like the 
one pictured in A, Figure 20. 
Before connecting to power source, be sure 
switch is in off position.  
It is recommended that the table saw, when 
operated on 115 volt power, be connected to a 
dedicated 20 amp circuit with a 20 amp circuit 
breaker or time-delay fuse marked “D”. When 
operated on 230 volt power, it is recommended 
that the table saw be connected to a dedicated 
15 amp circuit with a 15 amp circuit breaker or 
time-delay fuse marked “D”.  Local codes take 
precedence over recommendations. 
9.1  Grounding instructions 
1. All Grounded, Cord-connected Tools: 
In the event of a malfunction or breakdown, 
grounding provides a path of least resistance for 
electric current to reduce the risk of electric 
shock. This tool is equipped with an electric cord 
having an equipment-grounding conductor and a 
grounding plug. The plug must be plugged into a 
matching outlet that is properly installed and 
grounded in accordance with all local codes and 
ordinances. 
Do not modify the plug provided - if it will not fit 
the outlet, have the proper outlet installed by a 
qualified electrician. 
Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock. The conductor with insulation 
having an outer surface that is green with or 
without yellow stripes is the equipment-
grounding conductor. If repair or replacement of 
the electric cord or plug is necessary, do not 
connect the equipment-grounding conductor to a 
live terminal. 
 Check with a qualified 
electrician or service personnel if the 
grounding instructions are not completely 
understood, or if in doubt as to whether the 
tool is properly grounded. Failure to comply 
may cause serious or fatal injury.
 
Use only 3-wire extension cords that have 3-
prong grounding plugs and 3-pole receptacles 
that accept the tool's plug. 
Repair or replace damaged or worn cord 
immediately. 
2. Grounded, cord-connected tools intended for 
use on a supply circuit having a nominal rating 
less than 150 volts: 
This tool is intended for use on a circuit that has 
an outlet that looks like the one illustrated in A, 
Figure 20. An adapter, shown in B and C, may 
be used to connect this plug to a 2-pole 
receptacle as shown in B if a properly grounded 
outlet is not available. The temporary adapter 
should be used only until a properly grounded 
outlet can be installed by a qualified electrician. 
This adapter is not permitted in Canada. The 
green-colored rigid ear, lug, and the like, 
extending from the adapter must be connected 
to a permanent ground such as a properly 
grounded outlet box. 
3. Grounded, cord-connected tools intended for 
use on a supply circuit having a nominal rating 
between 150 - 250 volts, inclusive: 
This tool is intended for use on a circuit that has 
an outlet that looks like the one illustrated in D, 
Figure 20. The tool has a grounding plug that 
looks like the plug illustrated in D. Make sure the 
tool is connected to an outlet having the same 
configuration as the plug. No adapter is 
available or should be used with this tool. If the 
tool must be reconnected for use on a different 
type of electric circuit, the reconnection should 
be made by qualified service personnel; and 
after reconnection, the tool should comply with 
all local codes and ordinances. 
 
Figure 20 
9.2  Voltage conversion 
To switch the incoming power leads for 230 volt 
operation, follow the wiring diagram on the 
inside cover of motor junction box. To access