Grounding Instructions 
General Information 
  Electrical connections must 
be made by a qualified electrician in 
compliance with all relevant codes. This 
machine must be properly grounded to help 
prevent electrical shock and possible fatal 
injury.
 
This machine must be grounded. In the event of 
a malfunction or breakdown, grounding provides 
a path of least resistance for electric current to 
reduce the risk of electric shock.  
This band saw is pre-wired for 115 volt and is 
equipped with an electric cord having an 
equipment-grounding conductor and a 
grounding plug similar to that shown in Figure 6. 
The plug must be inserted into a matching outlet 
that is properly installed and grounded in 
accordance with all local codes and ordinances. 
Do not modify the plug provided. If it will not fit 
the outlet, have the proper outlet installed by a 
qualified electrician. 
 
 
Figure 6 
 
Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock. The conductor, with insulation 
having an outer surface that is green with or 
without yellow stripes, is the equipment-
grounding conductor. If repair or replacement of 
the electric cord or plug is necessary, do not 
connect the equipment-grounding conductor to a 
live terminal. 
Check with a qualified electrician or service 
personnel if the grounding instructions are not 
completely understood, or if in doubt as to 
whether the machine is properly grounded. Use 
only three wire extension cords that have three-
prong grounding plugs and three-pole 
receptacles that accept the machine’s plug. 
 
 
115 Volt Operation 
As received from the factory, your band saw is 
ready to operate at 115 volt power, using an outlet 
and a plug that look similar to those illustrated in 
Figure 6. 
A temporary adapter, which looks like the adapter 
illustrated in Figure 7, may be used to connect this 
plug to a two-pole receptacle as shown, if a 
properly grounded outlet is not immediately 
available. The temporary adapter should only be 
used until a properly grounded outlet can be 
installed by a qualified electrician.
  
The green colored rigid ear, lug or tab, extending 
from the adapter must be connected to a 
permanent ground such as a properly grounded 
outlet box, as shown in Figure 7. 
Check with a qualified electrician or service 
personnel if the grounding instructions are not 
completely understood, or if in doubt as to whether 
the tool is properly grounded.  
Make sure the voltage of your power supply 
matches the specifications on the motor plate of 
the Band Saw.  
 
 
Figure 7