Jet 16-32 plus ユーザーズマニュアル

ページ / 36
 
25
Trouble Probable 
Cause 
Remedy 
Conveyor belt out of adjustment. 
Readjust conveyor belt; see page 15. 
Drive or driven roller needs adjusting. 
Readjust; see page 16. 
Conveyor belt worn or defective. 
Replace conveyor belt; see pages 15 
and 16. 
Drive roller worn, bent, or varies in 
diameter side to side. 
Replace drive roller. 
Conveyor belt tracks 
to one side, or 
oscillates from side to 
side. 
Roller bushings elongated due to 
excessive wear. 
Replace bushings. 
Strip caught on inside edge of slot, or 
on inboard side of drum. 
Re-adjust the strip end in the slot 
and/or trim the abrasive edge. 
Abrasive strip is 
loose. 
Strip not cut properly. 
Re-cut and re-install abrasive strip. 
See pages 11 and 12. 
Excessive depth of cut. 
Reduce depth of cut. 
Excessive feed rate. 
Reduce feed rate. 
Inadequate dust collection. 
Increase airflow at dust port. 
Inadequate abrasive. 
Use an open-coat abrasive. 
Abrasive loads up 
prematurely. 
Stock fed at 90° angle to drum. 
Angle stock 60° if possible to avoid 
resin line buildup. 
Table height 
adjustment works 
improperly. 
Improper adjustment of height control. 
Readjust height control. See pages 
19. 
Bearing(s) out of alignment. 
Re-align bearings. 
Dust in drum. 
Remove material inside drum. 
Set screws loose in pulley or bearing. 
Re-tighten set screws. 
Abrasive fastener on drum loose 
(without abrasive strip in place). 
Insert abrasive strip, or replace 
fastener. 
Knocking sound while 
running. 
Drum bearing(s) worn. 
Replace drum bearing(s).