Milan mil-sm2401maf ユーザーガイド

ページ / 178
 
                                                                               
 
109
 
 
 
 
 
 
Port Enable: displays the POE port status. Y means the port is enabling. N means 
the  port  is  disabling  and  will  not  have  any  power  providing  but  the  port  still  can 
transmit the data packet. 
 
PwrLimitClass.: displays the power class limit status. N means the power class limit 
is  disabling.  Y  means  the  power  class  limit  is  enabling.  The  power  limit  class  will 
follow the value that set in the power limit max when is enabling. 
 
PwrLimitManag.: displays the POE management that will follow or will not following 
the priority rules. 
 
Detect  Legacy:  The  legacy  detection  is  to  identify  the  PD  devices  with  unique 
electrical signatures, that did not follow the IEEE 802.3af standard. 
 
Priority: the port priority for power supply’s priority. 1 = C (critical), 2 = H (High), 3 = L 
(Low). 
 
PowerLimitMax: per port power output to PD’s power limit. 
 
Fault Status: display the PD error status message. There are three error status and 
explain as following. 
  Null: It means there is no PD connected or the connected PD device status is 
normal. 
  POE management   
  Power Supply management