Aethra d2000 lite ユーザーズマニュアル
USER’S MANUAL ISDN TESTER AND ANALYZER D2000
PRO
/D2000Lite/D2000
Capture Msg
⇒ TE: Captures specific messages that are sent to the terminal.
Capture Msg
⇒ NT: Captures specific messages that are sent to the network.
Buffer Mode: Choose whether monitoring should stop when the memory’s space is
full, or older data should be overwritten.
full, or older data should be overwritten.
CRC4: Activate or deactivate the CRC4 procedure. PRI only.
Protocol: Choose the local singling protocol.
100
Ω termination: Choose if you want to add a 100Ω termination to the S/T socket.
This option can be used if the S/T bus is not correctly terminated in the connection
point of the device. The default value is NO. BRI-S only.
point of the device. The default value is NO. BRI-S only.
Gain RXA/RXB: It is possible to insert an amplifier for each side of the link. Only in
Monitor PRI mode.
Monitor PRI mode.
L2 ignore alarms: Timer used to ignore layer 1 alarms that are shorter than the
inserted value. Only in Monitor PRI mode.
inserted value. Only in Monitor PRI mode.
For the other parameters, refer to paragraph 3.3 COMMON SETUP.
5.3. BRI-U Monitoring (D2022 Option)
This accessory is used to monitor signalling over the D-channel between the
exchange and the user over a Basic access, when monitoring over the S/T interface
is not possible.
exchange and the user over a Basic access, when monitoring over the S/T interface
is not possible.
This is typical of the installation of NT1+ network terminations, in which the signalling
protocol for analogue interfaces can only be analyzed over the U interface.
protocol for analogue interfaces can only be analyzed over the U interface.
The D2022 is placed in series between the two wires of the U interface coming from
the exchange (LT) and the user network termination (NT). It connects to the device
by means of the cable supplied, with the 'V.11' and 'POWER OUT' connectors.
The D2022 is powered by the device, which can be powered with AC/DC adapter or
internal batteries. In the latter case, battery operation is reduced consequently.
the exchange (LT) and the user network termination (NT). It connects to the device
by means of the cable supplied, with the 'V.11' and 'POWER OUT' connectors.
The D2022 is powered by the device, which can be powered with AC/DC adapter or
internal batteries. In the latter case, battery operation is reduced consequently.
CHAPTER 5 - USING THE INSTRUMENT FOR MONITORING