Called address: Enter the possible X.25 number of the remote to call. It may be the
own number, if configured as bidirectional in the Central Office.
own number, if configured as bidirectional in the Central Office.
LCI start: Enter the value of the first LCI, assigned to the access to verify.
The test does not require the insertion of a specific number to call
in order to verify the valid LCI values.
in order to verify the valid LCI values.
Range: Enter the maximum number of LCI to verify, starting from the one entered
above.
above.
2.4.2. Running an X.25 Access Test
Connect the instrument to the tested access and continue as follows:
2
Select ‘Use this setup for testing’
3
Connect the instrument as displayed on the screen and
press the right cursor key.
press the right cursor key.
4
Start the test. The test results appear on the screen.
Note that:
The LED RUN goes on, and the START key changes to STOP. Use this key to stop
the test.
the test.
The instrument checks each link with TEI value from 0 to 63 and shows the test
result as indicated in the table below:
result as indicated in the table below:
CHAPTER 2 - PERFORMING AN AUTOMATIC TEST
31