Aethra d2000 lite ユーザーズマニュアル

ページ / 186
USER’S MANUAL                                                                                 ISDN TESTER AND ANALYZER D2000
PRO
/D2000Lite/D2000 
 
User to user information: Define the information you want to send with the USER-
TO-USER supplementary service. Data is entered in hexadecimal format.  
TEI management: Choose one of the TEI management preferences. The instrument 
manages both Point-to-Point and Point-Multipoint connections. 
CLIR/COLR: Activate or deactivate the Calling Line Identification Restriction (CLIR) 
and Connected Line Identification Restriction (COLR). 
CUG (Closer User Group): This supplementary service is used to define a closed 
group of users and create a private virtual network, in which only the members can 
communicate. Set the Closed User Group (CUG) value between: 
•  No request: CUG service is not requested 
•  Inside: to call a internal member of the CUG 
•  Outside: to call a user that doesn't belong to any CUG 
•  User (x): to call a user that belongs to a specific CUG, enter the CUG 
identification 
Call accept: Select the incoming calls that will be automatically answered by the 
instrument with the loopbox function. The function can be deactivated by setting the 
None value. See § 3.8. 
100
Ω termination: Choose if you want to add a 100Ω termination to the S/T socket. 
This option can be used if the S/T bus is not terminated correctly. The default value is 
NO. BRI-S only. 
Protocol: Choose the local singling protocol. 
 
Set the “LEASED LINE” value to perform tests without signalling 
protocol over the D channel\, i.e. Unframed BER. Use the 
“OTHER” parameter to capture signalling protocols not directly 
supported by the instrument in Monitor mode. See chapter 5
Protocol type: Define the operation mode of the active protocol between Master and 
Slave. When you select the instrument operation mode, i.e. TE or NT, the “Protocol 
type” parameter will be automatically set with the typical value for the configuration. 
 
Change the parameter in case of special use of the instrument 
only. 
CDN(type/plan): Set the Type of Number and the Called Party Numbering Plan. It is 
possible to select among Unknown , ISDN, Private and National. 1TR6, TN1R6, 
DASS, DPNSS don’t support the last two values. 
CHAPTER 3 - PERFORMING A MANUAL TEST 
39