Aethra d2000 lite ユーザーズマニュアル
USER’S MANUAL ISDN TESTER AND ANALYZER D2000
PRO
/D2000Lite/D2000
To power the U interface, use the LT-U adapter. See Appendix B for information on
connections.
connections.
Connect the LT-U ADAPTER to the “AUX” connector of the
AC/DC Aethra 531000971 adapter supply with the instrument.
AC/DC Aethra 531000971 adapter supply with the instrument.
After connecting the U connector of the instrument and the U line of the NT socket to
the LT-U ADAPTER, set Basic Access, LT-U mode, on the instrument. The functions
are the same as the NT-S mode.
the LT-U ADAPTER, set Basic Access, LT-U mode, on the instrument. The functions
are the same as the NT-S mode.
This mode also allows for making calls from one user terminal to the other one by
simulating a self-call. To do it, go to the “LOOPBOX” menu window and follow the
instructions given in paragraph 3.8.
simulating a self-call. To do it, go to the “LOOPBOX” menu window and follow the
instructions given in paragraph 3.8.
3.16. S/T-BUS Wiring Test (WT2000 option)
Use an S/T-BUS test to verify the correct installation of the S/T BUS. The instrument
detects polarity inversions, interruptions or short circuits between the bus pairs.
detects polarity inversions, interruptions or short circuits between the bus pairs.
The test must be performed when the ISDN connection is not active. To perform the
test the WT2000 option is necessary. This option consists in two adapters, one
Master (WT2000M) and one Slave (WT-Slave). Connect the WT2000M to the
instrument to the V.11 plug with the corresponding cable. Connect the WT2000M to
the tested bus and close the other bus end with the WT-Slave. Disconnect both the
NT and TE on the BUS, if any.
test the WT2000 option is necessary. This option consists in two adapters, one
Master (WT2000M) and one Slave (WT-Slave). Connect the WT2000M to the
instrument to the V.11 plug with the corresponding cable. Connect the WT2000M to
the tested bus and close the other bus end with the WT-Slave. Disconnect both the
NT and TE on the BUS, if any.
To ensure proper verification, make sure you have disconnected
the TE and the NT1 network termination from the S/T BUS.
the TE and the NT1 network termination from the S/T BUS.
For information on connections see Appendix B.
3.16.1. Setting up an S/T-BUS Wiring Test
No parameter setting is necessary for the test.
3.16.2. Running an S/T-BUS Wiring Test
When you have defined the setup for this test, continue as follows:
CHAPTER 3 - PERFORMING A MANUAL TEST