Aethra d2000 lite ユーザーズマニュアル

ページ / 186
USER’S MANUAL                                                                                 ISDN TESTER AND ANALYZER D2000
PRO
/D2000Lite/D2000 
 
To power the U interface, use the LT-U adapter. See Appendix B for information on 
connections. 
 
 
Connect the LT-U ADAPTER to the “AUX” connector of the 
AC/DC Aethra 531000971 adapter supply with the instrument. 
After connecting the U connector of the instrument and the U line of the NT socket to 
the LT-U ADAPTER, set Basic Access, LT-U mode, on the instrument. The functions 
are the same as the NT-S mode.  
This mode also allows for making calls from one user terminal to the other one by 
simulating a self-call. To do it, go to the “LOOPBOX” menu window and follow the 
instructions given in paragraph 3.8. 
3.16.  S/T-BUS Wiring Test (WT2000 option) 
 
Use an S/T-BUS test to verify the correct installation of the S/T BUS. The instrument 
detects polarity inversions, interruptions or short circuits between the bus pairs. 
The test must be performed when the ISDN connection is not active. To perform the 
test the WT2000 option is necessary. This option consists in two adapters, one 
Master (WT2000M) and one Slave (WT-Slave). Connect the WT2000M to the 
instrument to the V.11 plug with the corresponding cable. Connect the WT2000M to 
the tested bus and close the other bus end with the WT-Slave. Disconnect both the 
NT and TE on the BUS, if any.  
 
To ensure proper verification, make sure you have disconnected 
the TE and the NT1 network termination from the S/T BUS. 
For information on connections see Appendix B. 
3.16.1. Setting up an S/T-BUS Wiring Test 
No parameter setting is necessary for the test. 
3.16.2. Running an S/T-BUS Wiring Test 
When you have defined the setup for this test, continue as follows: 
CHAPTER 3 - PERFORMING A MANUAL TEST 
89