ISDN TESTER AND ANALYZER D2000
PRO
/D2000Lite/D2000                                                                                USER’S MANUAL
 
 
 
 
If in the COMMON SETUP page regarding V.24 interface, see § 
3.3.4.1, the field ‘Flow control’ is set at ‘Xon/Xoff’, displaying of 
control characters is forced at ‘NO’ because Xon/Xoff are control 
characters as well and so they have to be interpreted. 
Local echo: By setting this parameter at ‘YES’, the device reports on screen the 
characters or messages sent. 
3.17.2. Running an AT Terminal (TTY) Test 
Once the test configuration parameters have been set, continue as indicated below: 
 
Select ‘Use this setup for testing’. 
 
Connect the instrument as displayed on the screen and 
press the RIGHT CURSOR key.  
 
Start the test. 
 
To enter the characters or the messages to be sent. 
Now you will be able to send messages or characters: 
 
 
To enter capital letters characters. 
 
 
To enter small letters characters. 
 
 
Special characters. Es.: spacepunctuation, etc.. 
 
 
Hexadecimal characters. 
92
 
                           CHAPTER 3 - PERFORMING A MANUAL TEST