Aethra d2061 ユーザーズマニュアル
ADSL TESTER D2061
USER’S MANUAL
or the other. Therefore, if the circuit under test uses the fast path, refer to the FAST
results.
results.
FEC Forward Error Correction FEC indicates the number of super frames that had at
least one forward error correction in one of its 68 data frames.
least one forward error correction in one of its 68 data frames.
CRC: Cyclic Redundancy Check Error indicates that in the data stream, a received
CRC-8 code is not identical to the locally calculated CRC-8 code. It is a count of the
number of super frames that had an incorrect CRC in the path.
CRC-8 code is not identical to the locally calculated CRC-8 code. It is a count of the
number of super frames that had an incorrect CRC in the path.
HEC: Header Error Control indicates that an ATM cell with an incorrect HEC is
contained in the data stream. It is a count of the number of super frames that had at
least one ATM cell with an error HEC.
contained in the data stream. It is a count of the number of super frames that had at
least one ATM cell with an error HEC.
Link Drop #: In this field is displayed the number of attempts the device has carried
out in order to perform the test (if into COMMON SETUP page the field ‘Re-open
request’ is set to ‘YES’).
out in order to perform the test (if into COMMON SETUP page the field ‘Re-open
request’ is set to ‘YES’).
6.2.5. ATM cells statistic
This page shows statistics at ATM layer, among data displayed you can see
transmitted and received cells, counters regarding OAM maintenance cells received
and unmapped cells.
transmitted and received cells, counters regarding OAM maintenance cells received
and unmapped cells.
The left column displays results for the upstream signal (received by the ATU-C); the
right column shows results for the downstream signal (received by the ATU-R). The
first part shows the number of transmitted (UP) and received (DOWN) cells in FAST
or INTERLEAVED mode.
right column shows results for the downstream signal (received by the ATU-R). The
first part shows the number of transmitted (UP) and received (DOWN) cells in FAST
or INTERLEAVED mode.
Follows the counter of alarms regarding OAM maintenance cells received (DOWN)
which meaning is explained below:
which meaning is explained below:
AIS: Alarm Indication Signal, shows the presence of alarms detected on line.
RDI: Remote Defect Indication, counter of alarm indication sent by a remote device.
84