Aethra d2061 ユーザーズマニュアル

ページ / 122
USER’S MANUAL 
                                                                                          ADSL TESTER D2061 
 
Value in mV of the impulse both in transmission and reception. S/T only (Pulse).  
 
The instrument measures the values of the signal impulses on 
the S/T BUS both in monitor and simulation. The signal is 750 
mV 
± 10% (referred to the 50Ω test impedance) according to the 
ETSI standard. For information on installation (short bus – 
extended bus), see ETS 300 012. 
6.4. Reading the POTS line status 
 
If the AB2001N option is present and the instrument is 
configuring to operate over a normal POTS analog line, you can 
display the status of some POTS line parameters. 
Display page 1 of the available status information. 
6.5.  Reading the instrument status 
You can view the status of internal batteries or battery recharge at any time. 
 
Select page 4 (ISDN). 
If powered with batteries, the instrument displays the 
battery voltage. 
CHAPTER 6 - SMART STATUS 
 
87