Aethra d2001 nx ユーザーズマニュアル

ページ / 122
USER’S MANUAL 
                                          ISDN TESTER AND ANALYZER D2001
NX 
 
 
If there is an active loop, it’s not possible to change the protocol 
to avoid B channel lock problems. 
In simulation mode with P-P configuration you can send the RESTART message 
after selecting RESTART B-CHANNEL on the first line and then selecting the B 
channel. 
 
Selects RESTART B-CHANNEL. Simulation mode only. 
 
 
Selects the B channel and sends the RESTART message. 
In simulation, if the answering mode loopbox is set as Manual (see chapter 3.10), the 
device shows the icon “bell” for each compatible incoming call and the user may 
decide if answering or disconnecting the call manually. 
If the call is answered, the user can decide to connect the channel by making a loop 
or by putting it on audio. 
In case of 'LEASED LINE' (see chapter 3.4.4), you can manually make a loop or 
connect the audio on a specific channel in any state. 
If the channel is connected in audio mode, the cannel which was previously 
connected goes automatically in loop. 
 
To select CONNECT AUDIO / LOOP. Only in simulation 
mode. 
CHAPTER 6 - SMART STATUS 
81