< Remote control numbering function > 
By connecting multiple CD4620 monitors using RS-232C cables, you can control any one monitor or all the monitors by 
one remote controller. 
1. Assign arbitrary ID number to each of multi-connected CD4620 monitors using MONITOR ID. 
ID numbers 1 to 26 are selectable. 
It is recommended to assign sequential ID numbers from 1 and up. 
2. The remote control mode of the first CD4620 monitor is set to PRIMARY and those of the other monitors are set to 
SECONDARY. 
3. When you direct the remote controller at the remote control signal sensor of the PRIMARY monitor and press the 
DISPLAY button on the remote controller, the ID selection OSD appears at the upper left of the screen. 
 
 
 
ID number of the currently viewed monitor 
 
 
Select the ID number of the monitor you want to control using the +/- button on the 
remote controller. 
The ID of the monitor you want to control is displayed at the upper left of its screen. 
By selecting ALL, you can control all the multi-connected monitors. 
 
4. Direct the remote controller at the remote control signal sensor of the PRIMARY monitor. 
OSD appears on the monitor having the ID number you selected. 
 
NOTE: 
When the ID selection OSD is being displayed on the PRIMARY monitor, press the DISPLAY button on the remote 
controller again to cancel the ID selection OSD and then control the monitor you selected. 
 
HINT: 
If you set the remote control mode wrongly and remote control operation becomes unavailable, press any button on the 
control panel of the monitor to display the OSD screen and change the remote control mode using ADVANCED OPTION. 
By pressing and holding down the DISPLAY button on the remote control for 5 seconds or longer, the remote control 