Vidikron model 100t ユーザーズマニュアル

ページ / 76
48
Vidikron Vision Model 90t and Model 100t Owner’s Operating Manual
5.3 
Troubleshooting Tips
Table 5-1 provides some general guidelines for troubleshooting problems you may 
encounter with the Vision 90t/100t. 
If you encounter an issue not described here or in Section 3 (refer to Installation 
Considerations 
on page 15), or if the 
suggested solutions fail to resolve the problem, please 
contact your Vidikron dealer or Vidikron Technical Support. 
Table 5-1. Troubleshooting Chart 
Symptom
Possible Cause(s)
Solution
The projector does not turn on 
after initial installation. The 
power LED lights red after you 
press the power button. 
The Vision 90t/100t is not 
plugged in or the AC outlet 
is not active. 
Ensure that the Vision 
90t/100t is plugged in and 
that the AC outlet is active. 
The projector is on, but there is 
no video image on-screen. 
Incorrect source selection. 
Source component is not 
turned on. 
Select the correct source. 
Turn on the source. 
A projected image from a DVD 
is split or otherwise scrambled. 
DVD  player  is  set  to 
progressive scan mode. 
Turn off progressive scan 
on the DVD player. 
Connect the DVD player to 
the HD/RGB 1 or HD/RGB 2 
input. 
Image is too bright and/or 
lacks definition in the bright 
areas of the image. 
Contrast is set too high. 
Lower the contrast setting. 
Image appears “washed out” 
and/or dark areas appear too 
bright. 
Brightness is set too high. 
Lower the brightness 
setting. 
Colors in the image are 
swapped; for example, reds 
appear blue or vice versa. 
The Red/Pr, Green/Y or 
Blue/Pb outputs from the 
source are connected to the 
wrong inputs on the Vision 
90t/100t. 
Ensure that the source 
outputs are connected to 
the correct Vision 90t/100t 
input. 
Image geometry is incorrect.
Incorrect aspect ratio 
selection. 
Select the aspect ratio that 
best matches the source 
image and screen size (refer 
to Table 4-1). 
The projector will not turn 
back on after it was powered 
down, or the image disappears 
during operation. 
The projector will not turn 
on for two minutes after 
power-down, to protect the 
lamp. 
The lamp has failed. 
Wait two minutes until the 
LED at the front of the 
Vision 90t/100t turns red.