DIMENSIONS AND SPECIFICATIONS 
(for 23‘ CustomStyle
models)
DIMENSIONS AND SPECIFICATIONS
28
Installation Instructions
INSTALLING THE REFRIGERATOR
REFRIGERATOR LOCATION
• Do not install the refrigerator where 
the temperature will go below 60°F (16°C)
because it will not run often enough to maintain
proper temperatures.
• Do not install the refrigerator where 
the temperature will go above 100°F (37°C)
because it will not perform properly.
• Install it on a floor strong enough to support it
fully loaded.
CLEARANCES
Allow the following clearances for ease 
of installation, proper air circulation and plumbing
and electrical connections:
23‘ (33” wide),
23‘/25‘ CustomStyle
25‘, 26‘, 27‘, 29‘
Sides
1/8″ (4 mm)
1/8″ (4 mm)
Top
1″ (25 mm)
1″ (25 mm)
Back
1/2″ (13 mm)
1″ (25 mm)
70
1
4
″ (178.4 cm)
36″
(91.4 cm)
24″ (61 cm)
24″ (61 cm)
Cabinet
Water
Electrical
3/4″ (19 mm) Airspace 
(1/2″ [13 mm] Gap +
1/4″ [6 mm] Wall Plates)
25″ (63.5 cm)
Countertop
DIMENSIONS AND SPECIFICATIONS 
(for 25‘ CustomStyle
models)
*72
1
/
4
″ (183.5 cm) required for full adjustment 
of mobility wheels. If cabinets installed above
refrigerator have doors that are flush to the top of
the opening for the refrigerator, then an additional
1/8″ may be required to provide clearance for
cabinet doors to open freely.
36″
(91.4 cm)
24″ (61 cm)
72
1
4