DataCard 285 ユーザーガイド

ページ / 159
3-10
Using the printer
User’s Guide for the Magna™ Class Printer
To exit or stop the Status Monitor, double-click on the Status Monitor 
icon and select Exit. You should exit the Status Monitor when you 
receive instructions to do so.
You cannot exit the Status Monitor while printing a card.
Starting or quitting diagnostics
The Start Diagnostics button on the Status dialog box changes the 
Magna Class printer driver from printing mode to diagnostics mode. 
When you select this button, a message appears informing you that 
printing of cards will stop in diagnostics mode. 
You cannot start diagnostics mode while printing a card. Wait until all 
cards are printed and then click the Start Diagnostics button.
When you start diagnostics mode, additional tabs appear on the 
Status dialog box.
The Quit Diagnostics button on the Status tab changes the Magna 
Class printer driver from diagnostics mode to printing mode. When 
you select this button, a message appears informing you that the 
printer will reset; you can resume printing cards. The internal 
components will move into the position for printing cards.
If you have entered diagnostics mode and selected the Close 
button in the Status dialog box, a message appears that allows 
you to quit diagnostics before closing the Status dialog box.
Starting or quitting advanced setup
The Advanced Setup button on the Status dialog box changes the 
Magna Class printer driver from printing mode to advanced setup. 
After you start advanced setup, additional tabs appear on the Status 
dialog box.
You cannot start advanced setup while printing a card. Wait until 
all cards are printed, and then click Advanced Setup.
In advanced setup, you can change printing intensity, position of 
printing, and select a new overlay material type.
E
E
E
E
MagnaUserGuide.book  Page 10  Friday, May 5, 2000  1:09 PM