LXE mx6 参照ガイド
304 Scanner
Specifications
MX6 Reference Guide
E-EQ-MX6RG-E
Communication Port Specifications
See section titled “COM Ports” in Chapter 3 “Physical Description and Layout”.
USB communication at 12Mbps
RS-232 speed 115kbps
Power out at 500mA at 5V
RS-232 speed 115kbps
Power out at 500mA at 5V
COM 1
17-pin Serial Port
RS-232 Port, USB and Power Connection
Serial Port Pinout
PIN SIGNAL
PIN SIGNAL
1
+ USB
10
- USB
2 PWR
11 USB
DET
3
N / C
12
RI
4
N / C
13
DSR
5
N / C
14
RXD
6
N / C
15
RTS
7 GND
16 TXD
8 5V
OUT
17
CTS
9 DTR
COM 3 / 6
The IR operating envelope has a distance range of 2 cm (.79 inches) to 15 centimeters (6 inches)
with a viewing angle of 30 degrees.
with a viewing angle of 30 degrees.
COM 3 IR Port
Raw Infrared communication
COM 6 IrDA Port
Infrared communication using IrDA protocol