INSTALLATION MANUAL
POWER CONNECTIONS 
This appliance is manufactured with a neutral (white) power supply 
wire and a cabinet-connected green grounding wire.
Connect the appliance cable to the junction box through the UL-
listed conduit connector. Complete electrical connection according 
to local codes and ordinances. For preferred junction box location, 
see Figure 2, page 2.
  NOTE TO ELECTRICIAN: The armored cable leads supplied 
with this appliance are UL recognized for connection to larger 
gauge household wiring. The installation of the leads is rated 
at temperatures much higher than the temperature rating of 
household wiring. The current carrying capacity of the conductor 
is governed by the temperature rating of the installation around 
the wire, rather than the wire gauge alone.
 Improper connection of aluminum house wiring 
to copper leads can result in an electrical hazard or fire. Use only 
connectors designed for joining copper to aluminum and follow 
manufacturer’s recommended procedure closely.
    GENERAL NOTE FOR WIRE NUT APPLICATIONS: 
The proper size wire nut shall be placed over the stripped 
leads and the wire nut twisted until the wire nut can not be 
pulled from the leads. No conductor shall be exposed in the 
connection. 
4-WIRE CONNECTION
When installing to a 4-wire electrical system, new construction, 
mobile home and recreational vehicle or when local codes do not 
permit grounding through neutral.
  1   Disconnect the power supply.
  2   
In the junction box connect the appliance and residence cable 
wires as shown in Figure 17.
Red wires
Green wires
White wires (nutral)
Black wires
Conduit connector
(not supplied)
Appliance
conduit & wires
Power supply
3-WIRE CONNECTION
 
When local codes permit connecting the cabinet-grounding conduc-
tor to the neutral (white) wire. 
  1   Disconnect the power supply.
  2 
In the junction box connect the appliance and residence cable 
wires as shown in Figure 18.
Red wires
White wires (nutral)
Black wires
Green wire
(ground)
Conduit connector
(not supplied)
Appliance
conduit & wires
Power supply
REINSTALL JUNCTION BOX COVER
Do not shorten the flexible conduit. The conduit strain relief clamp 
(supplied by installer) must be securely attached to the junction box 
and the flexible conduit must be securely attached to the clamp. If 
the flexible conduit will not fit with the junction box, do not install 
the appliance until a clamp of proper size has been obtained.
Figure 18
Figure 17