DRAINAGE:
Fig. 23
SWING OPERATION:
When you turn on the unit, the louver will swing and stop at a certain angle. You 
can press the SWING button to let the louver swing automatically. Press the 
SWING button again while you want the louver stop at desired angle.
CHECK FILTER FEATURE:
This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more 
efficient operation. The LED (light) which above the "Filter" button will illuminate 
after 250 hours of operation. To reset after cleaning the filter, press the "Filter" 
button and the light will go off.
FAULT CODE:
If the display reads "EA" , the room temperature sensor has failed. Contact your Authorized 
Frigidaire Service Center.
If the display reads "ES" , the evaporator temperature sensor has failed. Contact your  
Authorized Frigidaire Service Center. 
If the display reads "E4" , the display panel communication has failed. Contact your 
Authorized Frigidaire Service Center.
If the display reads "P1" , bottom tray is full.  Carefully move the unit to a drain location, remove 
the bottom drain plug and let the water drain away. Restart the machine until the "P1" symbol 
disappears. If error repeats, call for service.
Operating Instructions
During the dehumidifying mode, you will need a 
garden hose (sold separately) to drain the condensate 
from the unit.
Remove the rubber stopper from the hose connector,
then screw on a garden hose  to the connector as shown 
on fig 23. 
The hose may then:
A. Discharge into a drain that is lower than the unit.
B. Be connected to a condensate pump (sold separately).
Remove the 
supplied rubber 
stopper  
Garden hose