Frigidaire FASG7073L インストール手順

ページ / 48
10
INSTALLATION REQUIREMENTS
Clearance requirements, continued
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES
REAR
TOP
FRONT
 Alcove
0” (0 cm) 0” (0 cm)* 0” (0 cm)
n/a
 Under-
 Counter 0” (0 cm) 0” (0 cm)* 0” (0 cm)
n/a
 Closet
0” (0 cm) 0” (0 cm)* 0” (0 cm) 1” (2.54 cm)
0”
(0cm)
0”
(0cm)
1”
(2.54cm)
0”
(0cm)
Dryer must be vented straight back to achieve 
0” (0 cm) rear installation.
60 sq. in.
(387.1cm²)
3”
(7.6cm)
60 sq. in.
(387.1cm²)
3”
(7.6cm)
closet door
Installation in a Recess or Closet
1  A dryer installed in a bedroom, bathroom, recess or 
closet, MUST be exhausted outdoors.
2  No other fuel burning appliance shall be installed in 
the same closet as the gas dryer.
3  Your dryer needs the space around it for proper 
ventilation.
DO NOT install your dryer in a closet with a solid door.
4  Closet door ventilation required: A minimum 
of 120 square inches (774.2 cm²) of opening, 
equally divided at the top and bottom of the 
door, is required. Openings should be located 3 
inches (7.6 cm) from bottom and top of door. 
Openings are required to be unobstructed when a 
door is installed. A louvered door with equivalent 
air openings for the full length of the door is 