MICROWAVE OVEN-TOUCH CONTROL
DISCONNECT POWER BEFORE SERVICING 
IMPORTANT-RECONNECT ALL 
GROUNDING DEVICES
ALL PARTS OF THIS APPLIANCE CAPABLE OF CON-
DUCTING ELECTRICAL CURRENT ARE GROUNDED. 
IF GROUNDING WIRES, SCREWS, STRAPS, CLIPS,
NUTS OR WASHERS USED TO COMPLETE A PATH TO
GROUND ARE REMOVED FOR SERVICE, THEY MUST
BE RETURNED TO THEIR ORIGINAL POSITION AND
PROPERLY FASTENED.
GROUNDING SPECIFICATIONS
Leakage Current 0.5 mA. (Max.) 
Ground Path Resistance 0.14
Ω
(Max.)
INSTALLATION REQUIREMENTS
ELECTRICAL
Power source
120VAC. 60Hz
Line Current
13.6Amps 1550W
Over Current Protection
15-20 Amps
Requires 120 volt, 15-20 amp parallel,
grounded separate circuit.
Working voltage
108-132 VAC
MICROWAVE LEAKAGE TEST
1. Plate 275ml. water in 600 ml. 
beaker (WB64 x 5010) 
2. Place beaker in center of oven shelf. 
3. Set meter to 2450 MHz scale. 
4. Turn "ON" for 5 minute test. 
5. Hold probe perpendicular to surface being tested and
scan surfaces at rate of one inch/sec. 
Test following areas: 
- Entire perimeter of door and control panel 
- Viewing surface of door window 
- Exhaust vents
6. Maximum leakage 4 MW/CM
2
.
7. Record data on surface invoice and microwave leak-
age report.
NOTE: Maximum allowable leakage is 5 MW/CM
2
.
4 MW/CM
2
is used to allow for measurement
and meter accuracy. 
Inform the manufacturer of any oven found to have
emission in excess of 5 MW/CM
2
. Make repairs to bring
the unit into compliance at no cost to owner and try to
determine cause. Instruct owner not to use oven until it
has been brought into compliance.
TECHNICAL DATA SHEET 
STANDARD TEST LOAD
The standard test load is one liter (1000ml.) water with
a starting temperature of 59°F~75°F in a 1000ml. Use
the beaker of WB64 x 0073. (DO NOT USE ANY
OTHER LOAD OR DISH AS RESULTS WILL VARY
FROM STANDARD.)
PERFORMANCE TEST
1. Measure line voltage(loaded). This test is based on
normal voltage variations of 105V to 130V. Low volt-
age will affect power and temperature rise.
2. Place WB64 x 0073 beaker containing exactly one
liter (1000ml. 59°F~75°F) water on glass shelf and
record the starting water temperature with an accu-
rate glass thermometer (Robinar no. 12084).
3. Set at HIGH (Power).
4. Turn oven "ON" and timer for exactly two minutes
and three seconds.
5. At end of time period, record the water temperature.
The difference between the starting and ending tem-
peratures is the temperature rise.
Depending on line voltage the minimum temperature
rise should be:
Line Volts 
Minimum Temperature Rise
120V 43°F
HlGH VOLTAGE CAPACITOR
The high voltage capacitor has an internal discharge
resistor to automatically discharge the capacitor when
the oven turns "OFF". Under normal operation, the
capacitor should fully discharge within 30 seconds.
CAPACITOR AND DIODE REMOVAL
1. Disconnect power and discharge capacitor. 
2. Disconnect capacitor and magnetron leads. 
3. Remove screw from capacitor strap. 
4. Remove capacitor strap.
INTERLOCKS AND MONITOR
The Primary, Door Sensing & Monitor switches are
mounted to a plastic latch board: on the right side of the
cavity. The Secondary interlock Relay (RY-2) is mount-
ed on the smart board. From top to bottom the switches
are as follows;
• Door Sensing 
• Monitor 
• Primary Interlock
HOW TO TEST PRIMARY INTERLOCK
1 Unplug oven, remove outer case, and discharge
capacitor. 
2. Check continuity of Switch:
• Door Closed: 0 
Ω
• Door Open: 
∞ Ω
MONITOR SWITCH
The Bottom Latch pawl pushes horizontally and actuates
the lever of the monitor interlock opening the switch .
HOW TO TEST MONITOR
1. Unplug oven, remove outer case and discharge
capacitor. 
2 Check 20 Amp. fuse for continuity and proper size. 
Do not use any other fuse or size except 20 Amp.  
3. Remove one monitor switch lead to isolate switch. Check
continuity of switch with door open and door closed.
• Door Closed: 
∞Ω
• Door Open: 0 
Ω
4. Reconnect switch wiring.
5. Test Circuit Operation. 
A) Connect temporary jumper across relay contacts,
primary interlock and door sense switches to simu-
late shorted switch contacts. Locate convenient
connections in circuit to be certain COM and N.O.
terminals are used. 
B) Connect ohm meter (Rx1) across the line terminals
of the appliance cord. Continuity must show:
• Door Closed: some 
Ω
• Door Open: 0 
Ω
C) Remove 20 Amp. fuse-circuit must open ( 
∞ Ω
). 
If not check wiring of monitor and interlocks. 
6. WARNING! After test remove temporary jumper leads
from interlocks and relay. 
7. Replacement of any parts or monitor circuit requires
repeating this entire test procedure.
NOTE:
Perform microwave leakage test when replacing
or adjusting interlock switches or latch board.
HOW TO TEST DOOR SENSING
Make continuity check between switch terminals. 
Normal reading are as follows:
• Door Closed: 0 
Ω
• Door Open: 
∞ Ω
HOW TO TEST INTERLOCK SYSTEM
Unplug oven, remove outer case, and discharge 
capacitor.
1. Power Relay (RY-2)
• Disconnect two leads from smart board relay.
• Check continuity across the terminals. 
The contacts should read open.
POWER RELAY (RY-2) & 
TURNTABLE CONTROL RELAY (RY-3)
REPLACEMENT
The Power relay and turntable control relay are mounted
on the control smart board and when it becomes faulty,
must be replaced as an assembly.
HOW TO ADJUST INTERLOCKS
The Latch-Board is adjustable for door fit and switch
operation.
1. Disconnect power, remove outer case, and discharge
capacitor.
2. Loosen switch housing mounting screw at enlarged
hole in vertical flange.
3. Adjust each switch housing for proper switch opera-
tion, and door fit. Retighten screws.
NOTE: 
Perform microwave leakage test when replac-
ing or adjusting interlock switches or brackets.
PRECAUTIONS TO BE
OBSERVED BEFORE AND
DURING SERVICING TO
AVOID POSSIBLE EXPO-
SURE TO EXCESSIVE
MICROWAVE ENERGY
A. MICROWAVE EMISSION CHECK SHOULD BE PER-
FORMED PRIOR TO SERVICING IF OVEN OPERA-
TIVE.
B. DO NOT OPERATE OR ALLOW THE OVEN TO BE
OPERATED WITH DOOR OPEN.
C. IF THE OVEN OPERATES WITH THE DOOR OPEN: 
1 ) INSTRUCT THE USER NOT TO OPERATE THE 
OVEN. 
2) CONTACT THE MANUFACTURER AND THE CEN-
TER FOR DEVICES AND RADIOLOGICAL HEALTH
IMMEDIATELY.
D. MAKE THE FOLLOWING SAFETY CHECKS ON ALL
OVENS TO BE SERVICED BEFORE ACTIVATING THE
MAGNETRON OR OTHER MICROWAVE SOURCE,
AND MAKE REPAIRS AS NECESSARY:
1. INTERLOCK OPERATION
2. PROPER DOOR CLOSING
3. SEAL AND SEALING SURFACES (ARCING, 
WEAR, AND OTHER DAMAGE)
4. DAMAGE TO OR LOOSENING OF HINGES AND 
LATCHES
5. EVIDENCE OF DROPPING OR ABUSE 
E. BEFORE TURNING ON MICROWAVE POWER FOR
ANY TEST OR INSPECTION WITHIN THE
MICROWAVE GENERATING COMPARTMENTS,
CHECK THE MAGNETRON, WAVE GUIDE OR TRANS-
MISSION LINE, AND CAVITY FOR PROPER ALIGN-
MENT, INTEGRITY, AND CONNECTIONS.
F. ANY DEFECTIVE OR MISADJUSTED COMPO-
NENTS IN THE INTERLOCK, MONlTOR, DOOR
SEAL AND MICROWAVE GENERATION AND
TRANSMISSION SYSTEMS SHALL BE REPAIRED,
REPLACED, OR ADJUSTED BY PROCEDURE
DESCRIBED IN THIS MANUAL BEFORE THE OVEN
IS RELEASED TO THE OWNER.
G. A MICROWAVE LEAKAGE CHECK TO VERIFY
COMPLIANCE WITH THE FEDERAL PERFOR-
MANCE STANDARD SHOULD BE PERFORMED ON
EACH OVEN PRIOR TO RELEASE TO THE
OWNER.
TO PREVENT ELECTRICAL SHOCK. USE EXTREME
CAUTION WHEN DIAGNOSING OVEN WITH OUTER
CASE REMOVED AND POWER "ON". THE HIGH
VOLTAGE SECTION OF THE POWER SUPPLY
INCLUDING FILAMENT LEADS IS 4000 VOLTS
POTENTIAL WITH RESPECT TO GROUND.
WARNING !  
When 20 Amp. fuse is blown due
to operation of monitor switch-both primary inter-
locks and the monitor switch must be replaced.
Also replace Relay (RY-2) when continuity
check shows contacts shorted.
WARNING ! 
Always be certain the capacitor is discharged before
servicing. Mechanically discharge by placing an 
insulated handle screw driver between the diode 
connection of the capacitor and oven chassis ground. 
NOTE: 
Use screw head close to capacitor to insure
ground metal contact.
IMPORTANT SAFETY NOTICE 
THIS INFORMATION IS INTENDED FOR USE
BY INDIVIDUALS POSSESSING ADEQUATE
BACKGROUNDS OF ELECTRICAL, ELEC-
TRONIC AND MECHANICAL EXPERIENCE.
ANY ATTEMPT TO REPAIR A MAJOR APPLI-
ANCE MAY RESULT IN PERSONAL INJURY
AND PROPERTY DAMAGE. THE MANUFAC-
TURER OR SELLER CANNOT BE RESPONSI-
BLE FOR THE INTERPRETATION OF THIS
INFORMATION, NOR CAN IT ASSUME ANY
LIABILITY IN CONNECTION WITH ITS USE.
100
200
300
400
500
PRIMARY
INTERLOCK
MONITOR
INTERLOCK
DOOR
SENSING
MOUNTING
SCREWS
MODELS
 GLMB186KS
 GLMB186KB
 PLMB186KC