Nortel 4000 ユーザーガイド
A-51
Appendix A RAC Parameters
Managing Remote Access Concentrators Using Annex Manager
input
_flow_control
specifies the method of flow control for input received from a device connected
to a serial port. You can enter:
to a serial port. You can enter:
•
none
to disable flow control.
•
start/stop
to designate flow control by recognizing xon and xoff
characters.
•
eia
to indicate that flow control is delegated to a lower level
(e.g., a parallel port).
input_is_activity
defines activity as input. If you choose
enabled
, the RAC sets the inactivity timer
when it receives input at the port.
input
_start_char
defines the control character sequence that restarts input if
input_flow_control
is
set to
start/stop
.
Type
Async
Values
none, start/stop, eia
Default
none
Lists
Async Port, Printer Port, Flow Control, Modem
Type
Async
Values
enabled or disabled
Default
enabled
Lists
Async Port, Dedicated Port, Idle Timer, Modem
Type
Async
Value
+ any character
Default
+
(displays as ^Q)
Lists
Async Port, Flow Control
Ctrl
Ctrl
Q