Gently pull the converter module from the switch by pulling
on the two captive screws.
on the two captive screws.
5
If you are installing a new converter module, follow the
instructions in
instructions in
6
If you are not installing an converter module, retrieve the
blank plate that ships with the OPTera Metro 1200 Ethernet
Service Module.
blank plate that ships with the OPTera Metro 1200 Ethernet
Service Module.
7
Line up the locking tabs on the blank plate with the
receptacles in the converter module slot of the switch. Press
firmly, and fasten the screws using a Phillips screwdriver.
receptacles in the converter module slot of the switch. Press
firmly, and fasten the screws using a Phillips screwdriver.
Refer to “Connecting the cable,” next, and
to continue.
Connecting the cable
Note:
The -48 V converter module cable used with
this converter module is shipped with the 200 watt RPS,
which fits into the BayStack 10 PSU.
which fits into the BayStack 10 PSU.