Lowrance lmf-400 ユーザーズマニュアル

ページ / 48
24
3. Use the 
UP
 and 
DOWN
 keys to enter how many gallons the tank will
hold and press 
ENTER
. You will then be directed back to the Bus
Devices list.
To configure Waste Water:
1
. 
Highlight
  W
ASTE 
W
ATER
 from the list of configuration options and
press 
ENTER
. A window will appear prompting you to input the tank
number.
2. Enter the tank number (1,2 or 3) and press 
ENTER
, which will launch
a tank size window.
3. Use the 
UP
 and 
DOWN
 keys to enter how many gallons the tank will
hold and press 
ENTER
. The Changing Device Settings window will
appear. You will then be directed back to the Bus Devices list.
To configure Live Well:
1. Choose 
L
IVE 
W
ELL
 from the list of configuration options and press
ENTER
, which will launch a window prompting you to input the tank
number.
2. Enter the tank number (1,2 or 3) and press 
ENTER
, which will launch
a tank size window.
3. Use the 
UP
 and 
DOWN
 keys to enter the size of the tank and press
ENTER
. You will then be directed back to the Bus Devices list.
To configure Oil:
1. Highlight 
O
IL
 from the list of configuration options and press 
ENTER
,
which will launch a menu with these options: Port Tank, Cen Tank 
 
and
Stbd Tank.
2. Select a tank and press 
ENTER
, which will call up a Setting Tank
Size window.
3. Use the 
UP
 and 
DOWN
 keys to enter the number of gallons the tank
will hold and press 
ENTER
. You will then be returned to the Bus
Devices List.
To configure Black Water:
1. Highlight 
B
LACK 
W
ATER
 from the list of configuration options and
press 
ENTER
, which will launch a window prompting you to input the
tank number.
2. Enter the tank number (1, 2 or 3) and press 
ENTER
, which will call
up a tank size window.
3. Use the 
UP
 and 
DOWN
 keys to enter how many gallons the tank will
hold and press 
ENTER
. You will then be directed back to the Bus
Devices list.
To Reconfigure Fluid Level:
1. Select a configured Fluid Level (Fuel Tank, Oil Tank, Black Water
Tank, Waste Water Tank, Fresh Water Tank, Live Well Tank) from the
Bus Devices list and press 
ENTER
.