You can change the sensitivity level whether you are in Auto Sensitivity 
mode or Manual Sensitivity mode. The adjustment method works the 
same in both modes, but it gives you slightly different results. 
Adjusting sensitivity in Auto Sensitivity Mode is similar to manually ad-
justing a car's speed with the accelerator pedal while cruise control is on. 
You can tell the car to run faster, but when you let off the gas the cruise 
control automatically keeps you from running slower than the minimum 
speed setting. In the unit, auto mode will let you increase sensitivity to 
100 percent, but the unit will limit your minimum setting. This prevents 
you from turning sensitivity down too low to allow automatic bottom 
tracking. When you change the setting with auto turned on, the unit will 
continue to track the bottom and make minor adjustments to the sensitiv-
ity level, with a bias toward the setting you selected. 
Adjusting sensitivity in Manual Sensitivity Mode is similar to driving a 
car without cruise control — you have complete manual control of the 
car's speed. In the unit, manual mode allows you to set sensitivity at 
100 percent (maximum) or zero percent (minimum.) Depending on wa-
ter conditions, the bottom signal may completely disappear from the 
screen when you reduce sensitivity to about 50 percent or less! 
Try adjusting sensitivity in both auto and manual modes to see how 
they work. 
To adjust sensitivity: 
1. Press 
MENU
|
ENT
2. The Sensitivity Control Bar appears. Press 
↓ to decrease sensitivity; 
press 
↑ to increase sensitivity. When it's set at the desired level, press 
EXIT
. (When you reach the maximum or minimum limit, a tone sounds.) 
 
 
Sonar Menu with Sensitivity command selected (left). The Sensitivity 