Citel 1000 仕様ガイド

ページ / 3
070707   
 
 
Page 1 of 3 
 
     
 Copyright 2007 Citel plc All Rights Reserved 
 
 
 
 
 
EXTender 1000U Dedicated Analog Line Specifications 
 
This  document  provides  any  customer  or  service  provider  with  the 
necessary specification information to provide dedicated line facilities to the 
EXTender 1000U.  
 
Recommended Line Specification:  
 
  Two wire private circuit  
  No signaling provisions  
  600 Ohm interface  
  Sealing current recommended  
  For short haul circuits and campus cable, no conditioning  
  For longer circuits (longer than 3 miles), recommend C1 or D1 conditioning 
at a power level of -12 dBm  
  PCM provision  hould be  lear channel 64 kilobit/s or robbed-bit signaling 56 
kilobit/s channel  
  NO ADPCM  
 
Technical Information: 
 
1000 Hz Loss Range (Min/Max) 
3dB to 20dB loss end-to-end at 1004 Hz 
 
Frequency Response Template 
Attenuation distortion relative to 1004 Hz level: 
 
0 to 16dB 
from  150 Hz thru 200 Hz 
0 to 12 dB 
from  200 Hz thru 300 Hz 
0 to 9 dB 
from  300 Hz thru 400 Hz 
0 to 6 dB 
from  400 Hz thru 500 Hz 
0 to 3 dB 
from  500 Hz thru 600 Hz 
0 to 1 dB 
from  600 Hz thru 1200 Hz 
0 to 3 dB 
from  1200 Hz thru 1800 Hz 
0 to 6 dB 
from  1800 Hz thru 2100 Hz 
0 to 9 dB 
from  2100 Hz thru 2500 Hz 
0 to 12 dB 
from  2500 Hz thru 2800 Hz 
0 to 16 dB 
from  2800 Hz thru 3700 Hz 
 
When plotted on a semi-log graph, the plot should be a smooth U-Shaped curve.