Citel 3000 ユーザーガイド

ページ / 120
Page 34 
EXTender 3000 System Administrator’s Guide (Definity)
Remote Module Installation
ISDN Line Checklist
The recommended ISDN line provisioning for your U or S/T interface ISDN line is:
ISDN CO Switch type:
U Interface: AT&T 5ESS and Nortel DMS100 or National ISDN NI-1
S/T Interface: ETSI NET3
Circuit Switched Voice and Data on both B channels (B1 and B2).
No call features are required on any B channels.
Must be capable of 56K or 64k Synchronous Data Calls, Clear Channel
Note: Specifications are subject to change without notice as technological or manufacturing 
changes warrant.
Ensure you have the proper ISDN line installed at the Remote module’s site.
Ensure you know the SPID/DN numbers (U Interface), TEI type, and Connect Rate (56K or 64K). 
You obtain this information from your local ISDN service provider when the ISDN lines are 
installed. Note, that the S/T interface uses MSN numbers (Multiple Subscriber Number) instead of 
a SPID or DN.
Ensure that you have registered the ISDN lines with your long distance carrier for ISDN DATA Ser-
vice, if required.