TABLE 1 – Display panel (continued)
Icon
Function
Drain valve indicator.
Light
Solid green to indicate start of drain cycle . 
Drain cycle occurs:
1)  To maintain nominal steam output during normal 
operation .
2)  During end of season shut down. (End of season shut 
down occurs after 72 hours of inactivity.) 
3)  If humidifier has operated for 168 hours without a drain 
cycle . 
4)  When humidifier is turned off. 
Flashes green (along with fill light) indicating drain and fill 
valves are pulsing to dislodge mineral deposits.
Flashes green when humidifier is turned off indicating 
canister is draining. When flashing stops, main power 
disconnect can be turned off and front panel can be opened.
Indicates canister needs to be replaced or humidifier 
requires other type of service.
Light
Flashes red when canister can no longer supply demand 
and needs to be replaced because electrodes have been 
corroded or coated with mineral deposits. Humidifier may 
continue to generate steam but at a reduced capacity.
Flashes red if humidifier with new canister cannot generate 
steam due to insufficient water conductivity after 96 hours of 
drain/fill activity. Approximately 1/10 teaspoon of table salt 
can be added to fill cup to increase conductivity of water.
Solid red if controller detects over-current between 
electrodes. Causes may include electrodes coated with 
mineral deposits, blocked drain, or defect in drain valve 
circuit. See Troubleshooting Guide.
The Digital Humidifier Control offers two modes of operation, Automatic or 
Manual. An explanation of both modes follows. (See 
Figure 2 on page 10 for 
Automatic Mode. See 
Figure 3 on page 11 for Manual Mode.)
When in the Automatic Mode, this system offers the following benefits:
• 
 you  will  receive  the  optimum  amount  of  humidity  so  that  your 
home and its furnishings are protected from the damaging effects 
of  excess  condensation  or  low  humidity  during  the  heating 
season.
  The  Control  automatically  adjusts  your  home’s  humidity  based 
on  the  outdoor  temperature,  increasing  the  time  maximum  comfort  is 
maintained .
• 
 Simple operation with few adjustments. In the Automatic Mode, the 
Control eliminates the need to manually adjust the control when outdoor 
temperature changes. It also eliminates the need to turn the dial setting to 
“OFF” during the summer season. 
OpERATING INSTRUCTIONS – DIGITAL HUMIDIFIER CONTROL
DIGITAL HUMIDIFIER CONTROL INDICATOR LIGHTS 
Call Dealer for Service: The red light indicates that the humidifier is not 
operating normally and that service is required.
Humidifier On: The green light indicates that the humidifier is operating 
normally .
BLOwER ACTIVATION
Set the Blower Activation Switch to “ON” to allow the Humidifier Control 
to activate the furnace fan for additional humidification. Refer to 
TABLE 4 – 
Operation Guide. This may be required if the humidifier is mounted on a 
heat pump or a furnace with short run cycles. 
When the Blower Activation switch is “ON”, the Humidifier Control will turn 
on the HVAC blower when humidity is required. In the “OFF” position, the 
humidifier will only operate if humidity is required and the HVAC system is 
operating . 
When  the  Blower  Activation  switch  is  “ON”,  the  Humidifier  Control  may 
periodically turn the HVAC blower on to sample the humidity of the air.