Calflame cr2000 ユーザーズマニュアル

ページ / 32
Page 8 
2007 Barbecue Grill and Cart Owner’s Manual
 
LTR20071038, Rev. B
Installation / Assembly
One side of the enclosure shall be completely 
open.
Enclosures that have four sides, complete with a 
top and bottom:
At least two ventilation openings at cylinder 
valve level shall be provided in the sidewall, 
equally sized, spaced at 180º (3.14 rad), and 
unobstructed. Each opening shall have a total 
free area of not less than one square inch per 
pound (7.1 cm²/kg) of stored fuel capacity, and 
not less than a total free area of 10 square 
inches (64.5 cm²).
Ventilation openings shall be provided at floor 
level and shall have a total free area of not less 
than one square inch per pound (7.1 cm²/kg) 
of stored fuel capacity and not less than a 
total free area of 10 square inches (64.5cm²).  
If ventilation openings at floor level are in a 
sidewall, there shall be at least two openings.  
The bottom of the openings shall be at floor 
level and the upper edge no more than 5 
inches (127 mm) above the floor. The openings 
shall be equally sized, spaced at 180º (3.14 
rad) and unobstructed.
Every opening shall have minimum dimensions 
so as to permit the entrance of a 1/8 inch (3.2 
mm) diameter rod.
Transporting and Storing LP Gas
Transport only one cylinder at a time. Ensure the 
cylinder is secured in an upright position with the 
control valve turned off and the dust cap in place. Store 
cylinders outdoors and out of reach of children. Do 
not store cylinders in a building, garage, or any other 
enclosed area.
1.
2.
a.
b.
c.
LP Gas
Tank Requirements
For plumbed-in LP installation, use a 
convertible regulator and set it for LP 
gas. 
Maximum line pressure for plumbed-
in propane is 14” WC (3.5 kPa). 
Minimum line pressure for propane is 
11” WC.
The grill unit must be used with the 
gas pressure regulator. The regulator 
will control and maintain a uniform 
gas pressure in the manifold. The burner orifices 
have been sized for the gas pressure delivered by the 
regulator.
WARNING: Attempting to operate the grill unit without 
the gas regulator installed could cause an explosion 
and possible death.
Cylinder Specification
Any LP gas supply cylinder used with this grill must be:
Constructed and marked in accordance with the 
Specifications for LP-Gas Cylinders of the U.S. 
Department of Transportation or the National 
Standard of Canada, 
CAN/CSA-B339, Cylinders, 
Spheres and Tubes for Transportation of 
Dangerous Goods; and Commission
, as applicable.
Approximately 12 inches in diameter and 18 inches 
high.
The maximum fuel capacity is 20 lbs. of propane, or 5 
gallons.  Full cylinder weight should be approximately 
38 lbs. (43.7 lbs. nominal water capacity.) Never fill the 
cylinder beyond 80% full.
Place the dust cap on the cylinder valve outlet 
whenever the cylinder is not in use. Only install the type 
of dust cap on the cylinder valve outlet that is provided 
with the cylinder valve. Other types of caps or plugs 
may result in leakage of propane.
LP Gas Hook Up
An enclosure for an LP gas cylinder shall be vented by 
openings at the level of the cylinder valve and at floor 
level. The effectiveness of the openings for purposes of 
ventilation shall be determined with the LP-gas supply 
cylinder in place.  This shall be accomplished in one of 
the following manners: