Panasonic AG-HPX500 ユーザーガイド

ページ / 152
64
Setting Time Data
C
h
ap
te
r 4 A
d
ju
st
m
en
ts a
n
d S
et
tin
g
s f
o
r R
ec
o
rd
in
g
Externally Locking the Time 
Code
The time code generator built into your AG-HPX500P/
E may be locked with an external generator. It is also 
possible to lock an external time code generator with 
the internal generator.
Connections for externally locking the 
time code (examples)
As illustrated, both the reference video signals and the 
time code must be input.
Example 1:  Locking the time code with 
external signals
TC IN
Reference 
time code
Reference 
video signal
GENLOCK IN
<Note>
• In addition to an HD Y reference signal, a composite 
video signal can also be input as reference signal. 
Example 2:  Connecting two or more AG-
HPX500P/Es with one another, 
with one being used as the 
reference device.
GENLOCK IN
TC IN
TC OUT
VIDEO OUT
GENLOCK IN
TC IN
TC OUT
VIDEO OUT
TC OUT
VIDEO OUT
Different camera
Reference device
<Note>
•  On all connected devices, set the setting menu TC 
VIDEO SYNCRO (OUTPUT SEL screen) to TC IN, GL 
SELECT (OTHER FUNCTIONS screen) to COMPOSITE 
and CMPNT/SDI SEL (OUTPUT SEL screen) to AUTO.
•  Setting the setting menu TC VIDEO SYNCRO to TC IN 
will supply the time code via TC IN to the next slave 
device without delay. 
To externally lock the time code
Follow the steps below.
1
Turn on the POWER switch.
2
Position the TCG switch at [F-RUN].
3
Set the COUNTER button to TC. 
4
Supply a phase-relationship reference 
time code (that conforms to the time 
code requirements) and reference 
video signals to the TC IN and 
GENLOCK IN connectors, respectively.
•  Now the built-in time code generator is locked with 
the reference time code.
•  When locked to an external time code generator, the 
time code is at all times locked to the external time 
code, which is displayed as a highlighted value on 
the counter indicator. Do not engage the recording 
mode during the few seconds it takes for the sync 
generator to stabilize. 
•  Once a slave relationship is established, the TC IN 
and GENLOCK IN connectors stay in slave status.  
Note that the following events release slave status. 
• When TC PRESET is performed
• When CAMERA mode and MCR mode are switched
• The power is turned off
• The time code mode is switched
• The TCG switch is set to R-RUN
*  The slave function locks the time code to the TC IN 
input and the device will use this time code even if 
time code input should subsequently cease. 
Setting the user bits when the time 
code is externally locked
To externally lock user bits, set the setting menu TC IN 
UB REGEN (RECORDING SETUP screen) to ON.
Regardless of an F-RUN or R-RUN setting of the TCG 
switch, the time code is slaved to user bit values input 
to the TC IN connector. 
For details, refer to [Setting Time Data] (page 58) and 
[Setting user bits] (page 60).