Information
Replacing the lamp unit
Lamp replacement procedure
Turn power off, wait until power indicator stops 
blinking red, then unplug the power cord from 
the wall outlet and confi rm that the area around 
the lamp unit has cooled down.
LAMP indicator
POWER button 
/POWER 
indicator
•  Please wait more than one hour for lamp replacement.
  [If you need to replace the lamp more urgently]
•  The Projection display has a forced cooling feature. After 
the POWER button is turned OFF, and during the fi rst 
minute of the normal cooling fan operation, press the 
VOL+ button on the Device Display and 
▲ button on the 
remote control at same time for more than 5 seconds. 
The cooling fan operates for about 10 minutes. The LAMP 
indicator fl ashes red 5 times every 5 seconds.
Remove the Front cover. Place your fi ngertips 
under the Front cover and pull it from the Device 
Display.
Front cover
Loosen the Lamp cover screw.
First read caution and warning labels on lamp 
cover. Then, loosen the lamp cover screw by 
using a screwdriver.
Lamp cover handle
Screwdriver
Lamp cover screw
Loosen the lamp unit screw with a screwdriver. 
Then, grasp the lamp unit as shown in the 
diagram, and slowly remove from the Device 
Display.
Lamp unit screw
Lamp unit handle
•  Because the lamp unit is hot immediately after its use, 
touching it may cause burns.
•  Please allow the lamp to cool before handling or replacing 
the lamp unit.
Insert the new lamp unit being careful of the 
insertion direction.
•  Press on the arrow mark making sure insertion is done 
correctly.
Replace the Lamp unit and cover screws. Tighten 
the lamp unit/cover screw with a screwdriver.
•  Properly dispose of old lamp. Please see page 98.
Note
Attach the lamp unit and lamp unit housing door securely. If 
the lamp unit and lamp unit housing door are not attached 
securely, the protective circuit will be activated and the lamp 
will not turn on. 
Replace the Front cover.
1
2
3
4
5
6
7
CAUTION
After lamp replacement, you must reset the lamp 
time. Refer to the instructions enclosed with the 
lamp unit (Part No.: TY-LA1000).