Whirlpool wed5800 インストール手順
12
Vent system chart
NOTE: Side and bottom exhaust installations have a 90º turn
inside the dryer. To determine maximum exhaust length, add one
90º turn to the chart.
inside the dryer. To determine maximum exhaust length, add one
90º turn to the chart.
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See “Determine vent path” in “Plan Vent System.” Avoid 90º
turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior
of the vent to secure vent.
turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior
of the vent to secure vent.
Install Leveling Legs
1. To protect the floor, use a large, flat piece of cardboard from
the dryer carton. Place cardboard under the entire back side
of the dryer.
of the dryer.
2. Firmly grasp the body of the dryer (not the top or console
panel). Gently lay the dryer on the cardboard. See illustration.
3. Examine the leveling legs. Find the diamond marking.
4. Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.
visible.
5. Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent.
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent.
Connect Vent
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured to
exhaust hood with a 4" (10.2 cm) clamp.
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured to
exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final position. Do not crush or kink vent.
3. (On gas models) Check to be sure there are no kinks in the
3. (On gas models) Check to be sure there are no kinks in the
flexible gas line.
4. Once the exhaust vent connection is made, remove the corner
posts and cardboard.
Level Dryer
Check the levelness of the dryer. Check levelness first
side to side, then front to back.
side to side, then front to back.
If the dryer is not level, prop up the dryer using a wood block. Use
a wrench to adjust the legs up or down and check again for
levelness.
a wrench to adjust the legs up or down and check again for
levelness.
Reverse Door Swing (Optional)
You can change your door swing from a right-side opening to a
left-side opening, if desired.
left-side opening, if desired.
Reversible Large Side-Swing Door
1. Place towel (A) on top of dryer to protect surface.
2. Open dryer door. Remove bottom screws from cabinet side of
2. Open dryer door. Remove bottom screws from cabinet side of
hinges (C). Loosen (do not remove) top screws from cabinet
side of hinges.
side of hinges.
3. Lift door until top screws in cabinet are in large part of hinge
slot. Pull door forward off screws. Set door on top of dryer.
Remove top screws from cabinet.
Remove top screws from cabinet.
4. Use a small, flat-blade screwdriver to gently remove
4 hinge hole plugs (D) on left side of cabinet. Insert plugs into
hinge holes on right side of cabinet.
hinge holes on right side of cabinet.
Number of
90º turns
or elbows
90º turns
or elbows
Type of
vent
vent
Box or
louvered
hoods
louvered
hoods
Angled
hoods
hoods
0
Rigid metal
Flexible metal
Flexible metal
64 ft (20 m)
36 ft (11 m)
36 ft (11 m)
58 ft (17.7 m)
28 ft (8.5 m)
28 ft (8.5 m)
1
Rigid metal
Flexible metal
Flexible metal
54 ft (16.5 m)
31 ft (9.4 m)
31 ft (9.4 m)
48 ft (14.6 m)
23 ft (7 m)
23 ft (7 m)
2
Rigid metal
Flexible metal
Flexible metal
44 ft (13.4 m)
27 ft (8.2 m)
27 ft (8.2 m)
38 ft (11.6 m)
19 ft (5.8 m)
19 ft (5.8 m)
3
Rigid metal
Flexible metal
Flexible metal
35 ft (10.7 m)
25 ft (7.6 m)
25 ft (7.6 m)
29 ft (8.8 m)
17 ft (5.2 m)
17 ft (5.2 m)
4
Rigid metal
Flexible metal
Flexible metal
27 ft (8.2 m)
23 ft (7 m)
23 ft (7 m)
21 ft (6.4 m)
15 ft (4.6 m)
15 ft (4.6 m)
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
A
B
C
D