Adcom gfa-7805 ユーザーズマニュアル

ページ / 16
9
automatically and normal operation will resume. If you 
are to avoid tripping the thermostat in the transformer 
continually, you must reduce the sound level demands, 
correct the load impedance of the loudspeakers, or both.
(8) Thermal Protection LEDs
The GFA-7805/7807 are provided with a thermal protection 
circuit which will shut down the individual amplifiers 
if its heatsink temperature reaches 85°C. The Thermal 
Protection LEDs will light whenever the thermal protection 
circuit in its respective channel has been triggered and the 
amplifier is inoperative. The thermal protection circuitry 
will typically be triggered by very high power demands 
into impedances much lower than the amplifier is capable 
of driving at those levels. If any amplifier channel’s 
output through the loudspeaker(s) ceases abruptly, and 
its Thermal Protection LED glows, you will know that its 
heatsink temperature has become unacceptably high 
and the circuitry is protecting the amplification devices. 
Please note that the Power LED (7) will remain on and the 
amplifier will still be energized. Once the temperature 
of the heatsink(s) drops to a safe operating level, that 
amplifier will automatically resume operation.
Activation of the Thermal Protection circuitry in any 
of the amplifiers in the GFA-7805/7807 is an indication 
that the amplifier has been over-driven or that the 
load the loudspeakers are presenting to the amplifier 
is unreasonably low. If you wish to prevent recurrent 
activation of the thermal protection circuitry, you must 
reduce the volume-level demands or correct the load 
impedance condition which may be causing activation of 
this circuitry.
(9) Distortion Alert LEDs
The Distortion Alert circuit is a unique ADCOM distortion 
detection system which reads all forms of non-linear 
distortion such as THD, IM, slew-induced, “clipping,” etc. 
The Distortion Alert LEDs will light when distortion reaches 
approximately 1% regardless of impedance, voltage/
current phase angle or the reactance of the loudspeakers 
which the amplifier is driving. Sometimes, when the 
amplifier is in use, the LEDs may occasionally flicker 
during high volume listening, particularly if you are driving 
low impedances. This flickering is no cause for concern. 
The LEDs are simply warning you that the amplifier is 
approaching its maximum power output into the particular 
loudspeakers you are using. If, however, the Distortion 
Alert LEDs glow brightly or are illuminated most of the 
time during playback, you are over driving the amplifier 
and should turn down your volume control to reduce 
the listening level, otherwise it may cause the Thermal 
Protection to be activated or, in extreme cases, damage 