Adcom gfa-7805 ユーザーズマニュアル

ページ / 16
RESOLVING PROBLEMS
Use the chart below to solve common situations that don’t require professional attention. If the steps stated in POSSIBLE 
SOLUTION do not resolve your problem, then please contact your ADCOM Dealer or call the ADCOM Customer Service 
Department. Any problems not covered here should be brought to the attention of your ADCOM Dealer or ADCOM 
Customer Service Department.
SYMPTOM 
POSSIBLE REASON  
POSSIBLE SOLUTION
Power LED does not 
AC Power Cord(s) not plugged in. 
Plug in AC Power Cord(s).
glow. No sound 
AC Fuse(s) failed. 
Replace AC Fuse(s).
 
Transformer thermal protection engaged. 
Wait until unit cools down. It will reset.
 
I2V DC triggering malfunctioning. 
Reset power switch manually. Check
 
 
connection of 12V DC trigger at source.
Power LED glows, 
Preamp or source unit is not on. 
Make sure whole system is on.
but no sound 
Connections in rear of amp are loose. 
Verify all connections on rear of amp.
One channel not 
INPUT(s) or OUTPUT(s) connector 
Verify both connections on that channel.
producing sound 
disconnected or loose.
 
Speaker disconnected. 
Verify connection at speaker.
 
Internal protection engaged. 
Bring to Dealer or Service Center.
Hum from all speakers 
Ground loop (difference in ground voltages 
If Cable TV is present (see Note 1).
at any volume 
between components). 
If Cable TV is not present (see Note 2).
Hum from all speakers 
Problem with source unit (CD, tape, etc.), 
Try different source (tuner, tape, etc.)
(hum goes up or 
or RCA cable connecting that source unit 
and/or different RCA cable.
down with volume) 
to the preamp.
Hum from the amplifier 
Some major appliance, dimmer, halogen or 
Make sure all appliances, dimmers and
itself 
fluorescent light is creating interference. 
suspect lights are off.
A special note on “hum:” When there is a low-volume “hum” audible throughout your speakers, even with the main 
volume turned all the way down, you have a common phenomenon known as a “ground loop.” A ground loop is basically 
a difference in ground voltages between two or more components which are connected electrically and which creates 
multiple current paths where there must only be one. This difference in potentials creates a 60Hz low-level sound 
(approximately a low A), that seems to “hum.”
It can be caused by adding new components to your system, but that does not imply there is anything electrically 
wrong with any new component. With the advent of audio/video and home theater systems, the problem has become 
commonplace. Generally, the cause is the Cable-TV incoming signal line. This new incoming line may add an additional 
ground at a different potential to the AC line ground of your other equipment (refer to Note I and 2, to troubleshoot
a hum problem).
Note 1: Cable TV systems can sometimes contribute to ground loop problems which cause “hum.” To determine if your 
cable system is the contributing factor, disconnect the Cable-TV incoming signal line (round, 75Ω) at the wall, or the first 
component the cable is connected to (i.e. the cable box, or VCR). If the hum is no longer present, you must insert a “75Ω 
Ground Loop Isolator” before reconnecting the line. You should check with your ADCOM Dealer to obtain one. If the “75Ω 
Ground Loop Isolator” works only partially or not at all, then please read Note 2 to complete the troubleshooting procedure.
Note 2: Make sure that the power amplifier is at least 6” from the Preamp and/or Processor. Usually putting another 
component between them is sufficient to minimize the hum. If this does not reduce the hum, turn the system off and 
disconnect all Inputs from the amplifier. If the hum still persists, then your Dealer or Service Center must examine the 
amplifier. If the hum disappears, try another set of RCA cables. Connect one RCA cable at a time to see if one specific 
cable is responsible. If any or all cables cause the hum to appear, then the preamp or processor should be evaluated for 
proper operation by your Dealer or Authorized Service Center.
12