3com 4200G インストールガイド

ページ / 4
2. XENPAK Optical Module  
2.1  Appearance and front panel  
 
Figure 4  Appearance of a XENPAK optical  module 
 
Figure 5  Front panel of a XENPAK optical  module  
2.2  Installation  
Step 1: Put on an ESD-preventive wrist strap and verify it is properly 
grounded. Then remove the XENPAK optical module from the package. 
 
Step 2: Loosen the two mounting screws on the small cover plate in the 
middle on the filler panel with a screwdriver and remove the small cover 
plate. 
 
Note: When installing a XENPAK optical module, you do not need to 
remove the entire filler panel. Just remove the small cover 
plate in the middle on the filler panel. 
 
Step 3: Hold the fastening screws on the front panel of the XENPAK 
optical module, and gently push the XENPAK optical module in along the 
slot guide rail until the XENPAK optical module is in close contact with the 
switch. 
 
Step 4: Tighten the fastening screws on the XENPAK optical module with 
a screwdriver to fix the XENPAK optical module on the filler panel.