3com S7906E インストール手順

ページ / 2621
 
1-6 
          The max allowed user number is 2048 per slot 
          Current user number amounts to 1 
          Current domain is aabbcc.net 
 
Silent Mac User info: 
         MAC Addr               From Port           Port Index 
 
GigabitEthernet2/0/1 is link-up 
  MAC address authentication is enabled 
  Authenticate success: 1, failed: 0 
 Max number of on-line users is 1024 
  Current online user number is 1 
          MAC Addr         Authenticate state           Auth Index 
          00e0-fc12-3456   MAC_AUTHENTICATOR_SUCCESS     29 
<Device> display connection 
Slot:  2 
Index=29  ,Username=00-e0-fc-12-34-56@aabbcc.net 
 IP=N/A 
 MAC=00e0-fc12-3456 
 
 Total 1 connection(s) matched on slot 2. 
 Total 1 connection(s) matched. 
RADIUS-Based MAC Authentication Configuration Example 
Network requirements 
As illustrated in 
, a host is connected to the device through port GigabitEthernet 2/0/1. The 
device authenticates, authorizes and keeps accounting on the host through the RADIUS server.  
MAC authentication is required on every port to control user access to the Internet.  
Set the offline detect timer to 180 seconds and the quiet timer to 3 minutes. 
All users belong to ISP domain 2000.  
The username type of fixed username is used for authentication, with the username being aaa and 
password being 123456
Figure 1-2 Network diagram for MAC authentication using RADIUS