3com S7906E インストール手順

ページ / 2621
 
 
1-9 
 
Follow the step below to upgrade the boot file (distributed IRF device): 
To do… 
Use the command… 
Remarks 
Specify a boot file for the next 
boot of an SRPU device on a 
member device 
boot-loader file file-url 
chassis chassis-number slot 
slot-number main | backup } 
Required 
Available in user view. 
 
 
You must save the file for the next device boot under the root directory of the device. You can copy 
or move a file to change the path of it to the root directory. 
To execute the boot-loader command successfully, you must first save the file for the next device 
boot under the root directory of the storage media on the active SRPU (distributed device) 
The names of the files for the next boot of the active SRPU and the standby SRPU may be different, 
but the versions of the files must be the same; otherwise, the device may not boot normally. 
(distributed device) 
 
Configuring Temperature Alarm Thresholds for a board 
You can set temperature alarm thresholds for a card by using the following commands. When the 
temperature of a card reaches the threshold, the device will generate alarms. 
Follow these steps to configure temperature alarm thresholds for a card: (distributed device) 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Configure temperature alarm 
thresholds for a card 
temperature-limit slot-number 
lower-value upper-value 
Optional 
By default, the temperature 
alarm thresholds for a card are 
as follows: 
Upper limit: 80°C (176°F) 
Lower limit: 0°C (32°F) 
 
Follow these steps to configure temperature alarm thresholds for a card: (distributed IRFing device) 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Configure temperature alarm 
thresholds for a card 
temperature-limit chassis 
chassis-number slot 
slot-number
 lower-value 
upper
-value 
Optional 
By default, the temperature 
alarm thresholds for a card are 
as follows: 
Upper limit: 80°C (176°F) 
Lower limit: 0°C (32°F)