3com S7906E インストール手順

ページ / 2621
 
1-12 
Configuring a UDP jitter test 
Follow these steps to configure a UDP jitter test: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Enter NQA test group view 
nqa entry admin-name 
operation-tag
 
— 
Configure the test type as UDP 
jitter and enter test type view 
type udp-jitter 
Required 
Configure the destination 
address for a test operation 
destination ip ip-address 
Required 
By default, no destination IP 
address is configured for a test 
operation. 
The destination IP address must be 
consistent with that of the existing 
listening service on the NQA 
server. 
Configure the destination port 
for a test operation 
destination port 
port-number 
Required 
By default, no destination port 
number is configured for a test 
operation. 
The destination port must be 
consistent with that of the existing 
listening service on the NQA 
server. 
Specify the source port number 
for a request 
source port port-number 
Optional 
By default, no source port number 
is specified. 
Configure the size of a probe 
packet sent 
data-size size 
Optional 
100 bytes by default. 
Configure the filler string of a 
probe packet sent 
data-fill string
 
Optional 
By default, the filler string of a 
probe packet is the hexadecimal 
number 00010203040506070809. 
Configure the number of 
packets sent in a UDP jitter 
probe 
probe packet-number 
packet-number  
Optional 
10 by default. 
Configure the interval for 
sending packets in a UDP jitter 
probe 
probe packet-interval 
packet-interval 
Optional 
20 milliseconds by default. 
Configure the time for waiting 
for a response in a UDP jitter 
test 
probe packet-timeout 
packet-timeout 
Optional 
3000 milliseconds by default. 
Configure the source IP 
address of a probe request in a 
test operation 
source ip ip-address 
Optional 
By default, no source IP address is 
specified. 
The source IP address must be 
that of an interface on the device 
and the interface must be up. 
Otherwise, the test will fail.