3com S7906E 参照ガイド

ページ / 2327
 
1-18 
Default Level 
2: System level 
Parameters 
interval: Startup query interval in seconds, namely, the interval between general queries the IGMP 
querier sends on startup, with an effective range of 1 to 18000.  
Description 
Use the igmp startup-query-interval command to configure the startup query interval on the current 
interface.  
Use the undo igmp startup-query-interval command to restore the system default.  
By default, the startup query interval is 1/4 of the IGMP query interval.  
 
 
By default, the IGMP query interval is 60 seconds, so the startup query interval = 60 / 4 = 15 (seconds).  
 
Related commands: startup-query-intervaligmp timer query.  
Examples 
# Set the startup query interval to 5 seconds on VLAN-interface 100.  
<Sysname> system-view 
[Sysname] interface vlan-interface 100 
[Sysname-Vlan-interface100] igmp startup-query-interval 5 
igmp static-group 
Syntax 
igmp static-group group-address [ source source-address 
undo igmp static-group { all | group-address [ source source-address ] } 
View 
Interface view 
Default Level 
2: System level 
Parameters 
all: Specifies to remove all static multicast groups that the current interface has joined.  
group-address: Multicast group address, in the range of 224.0.1.0 to 239.255.255.255.  
source-address: Multicast source address.