Replacing the Lamp
Plug in the lamp power connector.
9
*009-0818-01*
Disconnect the lamp power connector from
its plug in the projector. To do this, press
down on the latch on the top of the connector,
while pulling the connector out of the plug.
Place the latch over the tab in the projector.  
Make sure that the latch fully engages on the
tab. Then press the handle down to lock  
the lamp in place.
To remove the lamp, lift the handle upward 
and slightly back to disengage the alignment 
tab and fan ducting. If necessary, gently 
press down on the fan ducting. 
Lift the handle on the lamp to release the 
latch that holds the lamp in place. Then lift 
the latch off the tab inside the projector.
Loosen the two screws that fasten the lamp 
door to the bottom of the projector.
Insert a small bladed screw driver into the pry point 
and lift the lamp door off of the projector. 
To install the lamp, first align the tab on the 
bottom of the lamp with the slot inside the 
projector. Then align the duct on the rear of the 
lamp with the duct inside the projector. Press the 
lamp into place.
Install the lamp door, making sure to align the 
connector on the lamp door with the connector 
inside the projector. Tighten the two screws.
Plug in the power cord and turn on the projector. 
To reset the lamp timer, press and hold the 
Volume + and Volume - keys for 10 seconds.
Press
Pull
Recessed pry point
Lamp duct
Tab
Slot
Tab
Latch
Handle
!
Before replacing the lamp, turn the power 
off, and unplug the power cord. Allow the 
projector to cool for 60 minutes.
Latch
Latch
Tab
Tab
Handle
Handle
Handle
Lock
Alignment pin
on bottom 
of lamp
Fan duct