Infocus in38 参照ガイド

ページ / 39
34
Be extremely careful when removing the lamp housing. In the unlikely 
event that the lamp ruptures, small glass fragments may be generated. 
The lamp module is designed to contain most of these fragments, but 
use caution when removing it. Before replacing a ruptured lamp, clean 
the lamp compartment and dispose of cleaning materials. Wash hands 
after lamp replacement. 
 
Hg – Lamp contains mercury. Manage in accordance with local 
disposal laws. See www.lamprecycle.org.
5
Carefully remove the lamp module by grasping and lifting the metal 
bail wire. Dispose of the lamp in an environmentally proper manner. 
6
Install the new lamp module, making sure that it is properly seated. Be 
careful not to touch the interior components of the projector.
7
Snap the bail wire back into its flat position against the lamp module.
8
Tighten the screws on the lamp module.
9
Replace the lamp door and tighten the screws.
10
Plug in the power cable. Press the Power switch and button to turn the 
projector back on, then reset the lamp hour timer. 
Resetting the lamp timer
To reset the lamp timer, navigate to the Settings>Service menu and select 
Reset
 Lamp Hours
remove module
reset lamp time in Service menu