Architects’ and Engineers’ Specification
FP+ Series: Dedicated Touring Amplifiers
FP 6000Q
Item no. AES-FP6000Q_V2
L a b . g r u p p e n   a b   •   S w e d e n
  i n t e r n a t i o n a L   c o n t a c t   •   i n f o @ L a b g r u p p e n . c o m       |       u S   c o n t a c t   •   i n f o u S @ t c e L e c t r o n i c . c o m
w w w . l a b g r u p p e n . c o m
Overview: Channel Modes and Network 
The power amplifier shall provide four discrete channels of amplifica-
tion. Rear-panel switches shall enable bridging of adjacent channels 
to allow reconfiguration as a 2- or 3-channel amplifier, with increased 
power output available through the bridged channels. The amplifier 
shall employ a proprietary tracking Class D output circuit topology. 
The  amplifier  shall  be  equipped  with  sensing  and  communication 
circuits  to  allow  comprehensive  remote  control  and  monito-ring 
functions via a separate network bridge. The proprietary control and 
monitoring  network  shall  use  Cat-5  cable  for  interconnection,  and 
shall allow control and monitoring directly from the network bridge’s 
front-panel or, via the bridge, from an external PC running proprietary 
software.
Power Output and Performance
Maximum total output of all four channels shall be 6000 watts. In dis-
crete four-channel mode, each amplifier channel shall deliver maxi-
mum continuous output power as follows: 320 watts into 16 ohms, 
625 watts into 8 ohms; 1250 watts into 4 ohms; or 1500 watts into 
2  ohms.  Maximum  output  voltage  per  channel  shall  be  101  Vrms; 
maximum output current per channel shall be 27 Arms. In bridged 
mode, each bridged channel shall deliver maximum continuous out-
put power as follows: 1250 watts into 16 ohms; 2500 watts into 8 
ohms; or 3000 watts into 4 ohms.
Default  amplifier  gain  shall  be  35  dB,  with  rear-panel  adjustment 
from 23 to 44 dB in 3 dB increments, selectable for each channel. 
For bridged channels, the amplifier shall automatically compensate 
-6 dB gain internally to maintain operation of all channels at selected 
gain.
The  amplifier  shall  exhibit  the  following  performance  parameters 
with  gain  set  at  35  dB  and  VPL  (Voltage  Peak  Limiter)  at  101  V:  
Frequency response shall be 6.8 Hz to 34 kHz, +0/-3 dB at 1 watt 
into an 8 ohm load; channel separation shall be greater than 70 dB; 
and  signal-to-noise  ratio  shall  be  greater  than  112  dBA.  THD  at  1 
watt, 20 Hz – 20 kHz, shall be less than 0.1%; THD at 1 kHz shall be 
no more than 0.05% at 1 dB below clipping.
A VPL shall limit peak output as determined by rear-panel switches. 
In  discrete  four  channel  mode,  peak  voltage  shall  be  selectable  in 
eights steps across a range of 101 V to 38 V. In bridged mode, peak 
voltage shall be selectable in eight steps from 202 V to 76 V. The 
voltage limiter mode shall be selectable for either Hard or Soft limit-
ing characteristics.
Connectors, Controls, and Indicators
The following connectors and controls shall be on the ReAR-PAneL 
of the amplifier. The four input connectors shall be electronically ba- 
lanced  XLR-F.  The  four  output  connectors  shall  be  either  binding 
post or neutrik Speakon. A group of seven DIP-switches shall de-
termine the following: amplifier gain (23 dB to 44 dB in 3 dB incre-
ments); option active; fan masked; and bridged mode selection for 
channel pairs. A group of sixteen DIP-switches shall determine VPL 
values for each channel (selectable in eight steps), and Hard or Soft 
limiting characteristic. Two ethercon-housed RJ45 connectors shall 
be provided for input and output of the control/monitoring network 
signals. An LeD adjacent to the RJ45 connectors shall indicate active 
or inactive status of the network.
The following indicators and controls shall be on the FRonT-PAneL 
of the amplifier. Four level control potentiometers shall be detented 
and provide attenuation from 0 dB to infinity in 21 steps. Individual 
switches shall be provided for power on/off and remote power on/off 
enabling. Front-panel LeD indicators shall be provided to show status 
of power on/off (green), network connection (blue), and PAL (Power 
Average  Limiter)  (red).  Additional  LeD  indicators  shall  be  provided 
to show the status of the following for each channel: signal present 
and high-impedance warning (green/red), signal present from -20 dB 
to -4 dB (4x green), VPL clipping (red), CPL (Current Peak Limiter) 
active (orange), VHF (Very High Frequency) warning (yellow), high 
temperature  warning  (yellow  flashing),  and  high  temperature  fault 
with output muted (yellow constant), and Mute (red).  
Power Supply, Protection, and Cooling 
The power supply shall be a regulated switch mode type. The ampli -
fi er shall operate from AC line sources of either 230 V nominal or 115 
V nominal, with operating ranges of 130 – 265 V and 65 – 135 V at 
line frequencies of 50 Hz or 60 Hz. Minimum power-up voltages are 
171 V (230 V nominal) and 85 V (115 V nominal). A soft start circuit 
shall limit current inrush at power-up to 5 A. The amplifier shall be 
equipped with a PAL circuit to prevent excessive current draw. The 
amplifier  shall  be  cooled  by  two  temperature-controlled,  variable-
speed fans, with air flow from front-to-back. An adaptive fan on/off 
function shall be dependent on presence of an output signal. 
Physical 
The amplifier shall be 483 mm (19 in.) wide, 88 mm (3.5 in / 2 U) 
high, and 396 mm (15.6 in.) deep. The weight shall be 12 kg (26.4 
lbs).  The  cabinet  shall  be  black  painted  steel  with  a  black  painted 
steel and aluminum front-panel. 
The  amplifier  shall  be  approved  for  use  as  specified  by  Ce,  
AnSI/UL, eTL and the FCC. The amplifier shall be the Lab.gruppen 
FP 6000Q.