Lab.gruppen ip 1350 仕様ガイド

ページ / 2
POWER AMPLIFIERS
iP 1350
SPECIFICATIONS iP 1350
Lab.gruppen AB, Gullregnsvägen 16, S-434 44 Kungsbacka, Sweden.
Tel. +46 300 168 23. Fax +46 300 142 46.  e-mail: info@labgruppen.se www.labgruppen.se
LAB. GRUPPEN reserve the right to alter functions or specifications without prior notice.
MAX  OUTPUT POWER 
1)
EIA at 1 kHz and 1% THD
FTC 20-20kHz @0.1%THD
Ω
 per channel
300 W
280 W
Ω
 per channel
500 W
460 W
Ω
 per channel
700 W
2)
660
2) 
W
Ω
 bridged
1000 W
920 W
Ω
 bridged
1400 W
2)
1320
2)
 W
Max output voltage
8 ohms load
49 Vrms
Peak voltage, no load
77 V
Distortion etc.
THD 20Hz-20kHz
and 1W to full power
0,03 %
THD @ 1kHZ and –1dB
under clip
0,005 %
DIM 30 at –3dB under clip
0,005 %
Hum and Noise
<-110 dB
Channel separation @10kHz
70 dB
Output impedance
30 m
Ω
Slew Rate
45 V/
µ
s
Inputs
Gain, selectable
[dB]
20, 23, 26, 29,
32, 35, 38, 41
Impedance
20 kohm
Common mode rejection
50 dB
Front Panel
Gain controls
(2) channel A, B
31 positions detent
Protect indicator
(2) yellow LEDs
80
°
C at heatsink or >12kHz at full power or shorted output
Clip Indicator
(2) red LEDs
Fast peak – slow release
Signal present indicator
(2) green LEDs
-40 dB below full output
On Indicator
(2) green LEDs
DC rail voltage for channel A and B
Rear Panel
Input connectors
(2) Neutrik Combo XLR type, 3 pin & 1/4” jack
Input /Link connector
(2) 3-pin Phoenix terminal block
Output connectors
(2) Neutrik 4-pole Speakon connectors
Switches
Clip limiter A and B
On-Off (switchable)
Link-switch
Ch.A-B
Power
230 V version
115 V version
Operation voltage
130 V-265 V AC
65 V – 135 V AC
Minimum start voltage
190 V
95 V AC
Full output power at 4ohms
230 V AC
115 V AC
Peak inrush current (Soft start limited) 20 A
10 A
Current Draw @ 4ohms&230V
Quiescent power (no load)
0.6 Arms
1.2 Arms
1/8 of full power (-9dB)
3.5 Arms
7 Arms
1/3 of full power (-5dB)
5.5 Arms
11 Arms
At full power (0 dB)  @1 kHz 1% THD
9.5 Arms
19 Arms
Net Dimensions mm (inch)
483 (19”) W x 88 (3,5”) H x 325 (12.8”) D
Shipping Dimensions mm (inch)
560 (22”) W x 180 (7.1”) H x 500 (19.7”) D
Net Weight
15 kg (33 lbs)
Shipping Weight
16.6 kg (36.5 lbs)
Approvals
CE
Emission
EN 55 103-1, E3
Immunity
EN 55 103-2, E3, with S/N below 1% at normal operation level
 4)
Safety
EN 60 065, class I
THX
iP1350T
1) Specifications measured with 230 VAC
4) Normal operation level 1/8 of full power or –9dB below clip level.
2) Component tolerance dependent
3) Continuous power, one channel driven or peak power both channels driven
(Thermal protection may occur at high continuous power)
The iP 1350 is a space-saving power amplifier, ideal for use in
installations as well as in cost-effective live sound systems.
The Iron Power (iP) family of power amplifiers is the new compact and
versatile line of professional power amplifiers with classic toroidal iron
transformers. To achieve a compact design, the latest semiconductor techno-
logy is utilized. This, together with Lab.gruppen’s proprietary copper cooling
system, Intercooler®, enhances the 2 ohms capacity.
A new Bi-phase wiring scheme also increases the capacity of the power
supply. This extends the power bandwidth in the low end.
Besides the traditionally superb Lab.gruppen sonic performance, there is a
full line of features to make the iP family functional in all situations from
installation to cost-effective live sound systems:
Multiple positions Gain switch
To meet the demands for a flexible gain structure in the system, Lab.gruppen
offers a multiple position gain switch. The maximum amplifier gain can be set
to all industry standards: 20, 23, 26, 29, 32, 35, 38 and 41 dB.
Versatile input connection
With the Neutrik Combo-jack we offer both the professional XLR-type
standard and the semi-pro 1/4” TRS phono-jacks. For installations the 3-pin
Phoenix terminal block may be handier.
Soft Start
Toroidal transformers require a huge amount of start current to build up a
magnetic flux when the amplifier is switched on. Therefore Lab.gruppen have
included a soft start circuit to minimize the risk of blowing the wall fuse and to
reduce flickering in the lighting.
Sophisticated protection circuitry, combining:
– ALS™ short circuit protection; the Adaptive Limiting System permits very
high peak currents, but keeps the amplifier within the Safe Operation Area.
– DC protection; protects against infrasonic signals
– VHF protection; protects the loudspeakers against strong very high
frequency non-musical signals above the audible range.
– Thermal protection; prevents the amplifier from being overheated. The
protection indicators on the front panel are switched on, as a warning, before
the protection process is initiated.
– AC protection; shuts down the power supply if the line voltage is outside the
operating voltage.
– Clip limiter; prevents severely clipped waveforms from reaching the
loudspeakers, whilst maintaining full peak power.
KEY FEATURES:
2 x 300 watts @ 8 
Ω
2 x 500 watts @ 4 
Ω
2 x 700 watts @ 2 
Ω
(Measured just below clip level,
with both channels driven)
◆ Compact design:
2U high
◆ Intercooler
®
 cooling
system with front-to-rear
airflow
◆ Multiple positions gain
switch
◆ Easily accessible dust filter
◆ Improved low-end power
bandwidth
◆ Neutrik Combo jack and
Phoenix terminal block
input connectors
◆ Bridged mono outputs in
one SpeakOn connector
2002-03 V1