Greenlee 860-1 ユーザーガイド

ページ / 16
860 PVC Heating Blankets
Greenlee Textron / Subsidiary of Textron Inc.
7
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815/397-7070
Voltage:
The 860-1-1/2, 860-3 and 860-4 require 120 volts AC.
Specifications
Approximate Warm-up Time
 3
Blanket
Conduit
Voltage
Power
Max-Bend
Minutes (70
°
 F Ambient)
Required
Size
Required
Required
Angle
Sch. 40
Sch. 80
EB, DB
860–1-1/2
1/2
120 VAC
200 Watts
90
3-4
4-5
860–1-1/2
3/4
120 VAC
200 Watts
90
4-5
5-6
860–1-1/2
1
120 VAC
200 Watts
90
5-6
6-7
860–1-1/2
1-1/4
120 VAC
200 Watts
45
6-7
7-8
860–1-1/2
1-1/2
120 VAC
200 Watts
45
6-7
7-8
4-5
860–3
2
120 VAC
800 Watts
90
7-8
7-8
4-1/2–5
860–3
2-1/2
120 VAC
800 Watts
60
8-10
11-13
860–3
3
120 VAC
800 Watts
60
10-12
12-14
8-12
860–4
3–1/2
120 VAC
1300 Watts
60
8-10
12-14
6-10
860–4
4
120 VAC
1300 Watts
30
8-10
12-14
6-10
1
This is the maximum length which can be treated in one trial to form a bend approximately five times the conduit size.
2
Actual times may vary based on ambient temperature, wind conditions, if outside, and line voltage. (See recommended
extension cord on previous page.)
3
Schedule 20 heating times are slightly faster.
4
Type EB and DB duct heating times are approximately 2/3 of Schedule 40. Do not heat longer than necessary or
marking may occur.