Pioneer VSX-21TXH ユーザーガイド

ページ / 123
The Advanced MCACC menu
10
85
En
2
Select an option and press ENTER.
• Reverb Measurement – Use this to measure the 
reverb characteristics before and after calibration. 
(For graphical output using a PC, see Connecting a 
PC for Advanced MCACC output
 on page 36 to 
connect an RS-232C cable before selecting this 
option.)
• Reverb View – You can check the reverb 
measurements made for specified frequency ranges 
in each channel.
1
 This can also be used to compare 
the reverb characteristics before and after 
calibration.
2
• Advanced EQ Setup – Use this to select the time 
period that will be used for frequency adjustment and 
calibration, based on the reverb measurement of 
your listening area. Note that customizing system 
calibration using this setup will alter the settings you 
made in Automatically setting up for surround sound 
(Auto MCACC)
 on page 41 or Automatic MCACC 
(Expert)
 on page 78 and is not necessary if you’re 
satisfied with these settings.
3
If you selected ‘Reverb Measurement’, select EQ 
ON or OFF, and then START.
The following options determine how the reverb 
characteristics of your listening area are displayed in 
Reverb View and Output PC (see Connecting a PC for 
Advanced MCACC output
 on page 36):
• EQ OFF – You will see the reverb characteristics of 
your listening area without the equalization 
performed by this receiver (before calibration). 
• EQ ON – You will see the reverb characteristics of 
your listening area with the equalization performed 
by this receiver (after calibration).
3
 Note that the EQ 
response may not appear entirely flat due to 
adjustments necessary for your listening area.
4
When the reverb measurement is finished, you can select 
Reverb View to see the results on-screen. See 
Professional Calibration EQ graphical output on page 102 
for troubleshooting information.
4
If you selected ‘Reverb View’, you can check the 
reverb characteristics for each channel. Press RETURN 
when you’re done.
The reverb characteristics are displayed when the Full 
Auto MCACC
 or Reverb Measurement measurements 
are conducted.
5
Use 
/ to select the channel, frequency and 
calibration setting you want to check. Use 
/ to go 
back and forth between the three. The reverb 
characteristics graph before and after EQ calibration can 
be displayed by selecting Calibration : Before After.
6
 
Note that the markers on the vertical axis indicate 
decibels in 2 dB steps.
Note
1 If  the  Reverb View procedure is performed after the Automatically setting up for surround sound (Auto MCACC) on page 41 or Reverb 
Measurement operation, depending on the standing wave control setting, differences may appear on the reverb graph. With the Auto MCACC 
function, the reverberations are measured with the standing waves controlled, so the reverb characteristics graph shows the characteristics 
with the effect of the standing waves eliminated. By contrast, the Reverb Measurement function measures the reverberations without 
controlling the standing waves, so the graph indicates the reverb characteristics including the effect of the standing waves. If you wish to 
check the reverb characteristics of the room itself (with the standing waves as such), we recommend using the Reverb Measurement 
function.
2 The reverb characteristics after calibration can be displayed even after performing the Full Auto MCACC function (Automatically setting up 
for surround sound (Auto MCACC) on page 41). In this case, the display shows the predicted reverb characteristics after calibration. If the 
measurements are taken using the Reverb Measurement command (page 85) with the equalizer on, the actually measured reverb 
characteristics after calibration are displayed.
MCACC : 
M1.MEMORY 1
1c5a.Reverb Measurement
A/V RECEIVER
Exit
Cancel
  
START
Reverb Measure with : 
EQ OFF
3 • The calibration corresponding to the currently selected MCACC preset will be used when EQ ON is selected. To use another MCACC preset, 
exit the HOME MENU and press MCACC to select it before pressing HOME MENU.
• The predicted reverb characteristics after calibration can be acquired with the Full Auto MCACC function (Automatically setting up for 
surround sound (Auto MCACC)
 on page 41), but here the actually measured reverb characteristics after calibration can be acquired.
4 After auto calibration with EQ Type : SYMMETRY (Full Auto MCACC, etc.), the graph for the inferred reverb characteristics can be displayed 
by selecting Reverb View. To display the actually measured reverb characteristics after EQ calibration, measure with EQ ON.
5 The After display when measurements have been made using the Full Auto MCACC or Auto MCACC (ALL) function shows the graph for the 
inferred reverb characteristics after EQ Type : SYMMETRY calibration.
6 The reverb characteristics graph is overwritten each time the reverberations are measured. No Data is displayed if there is no reverb 
characteristic data, for example before measurements have been taken.
1c5b.Reverb View
Exit
Return
Channel :  Front 
M1.MEMORY 1
Calibration : 
After
Frequency : 
63Hz 
     SYMMETRY
A/V RECEIVER
dB
53.0
55.0
57.0
59.0
61.0
63.0
16 kHz
8 kHz
4 kHz
2 kHz
1 kHz
500 Hz
250 Hz
125 Hz
63 Hz
0
40
80
120
160 ms
VSX-23TXH_CUXJ.book  85 ページ  2009年5月8日 金曜日 午前10時45分