Bunn Dual SH ユーザーガイド

ページ / 34
Page 18
CIRCUIT BREAKERS
CA
UTION
CAUTION
DI
SC
AR
DE
CA
NT
ER
DISCARD DECANTER
IF:
IF:
. C
RA
CK
ED
. CRACK
ED
. S
CR
AT
CH
ED
. SCRATCHED
. B
OI
LE
DR
. BOILED DRY 
. H
EA
TE
W
HE
EM
PT
Y
. HEATED WHEN EMPTY
. U
SE
ON
 H
IG
FL
AM
E
. USED
 ON
 HIGH 
FLA
ME
. O
EX
PO
SE
EL
EC
TR
IC
. OR EXPOSED ELECTRIC
  E
LE
ME
NT
S
  ELEMENTS
FA
ILU
RE
 TO
 C
OM
PL
RI
SK
IN
JU
RY
FAILURE TO COMPLY RISKS INJURY
PN
: 6
58
PN: 65
8
19
85
 B
UN
N-
O-
MA
TIC
 C
OR
PO
RA
TIO
N
198
5 BUNN-
O-MATIC CORP
ORATION
FU
NN
EL
 C
ON
TE
NT
S
FUNNEL CONTENTS
    
    
AR
HO
T
        ARE HOT
!
!
CA
UT
IO
N
HO
T W
AT
ER
Location:
The circuit breakers are located on the lower front
of the brewer, mounted on the server platform just
above the spring contact receptacle assembly.
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Remove the wires from the circuit breaker.
3. Check for continuity between the terminals. Con-
tinuity must be present between the terminals.
If continuity is present as described the circuit breaker
is functioning properly.
If continuity is not present as described, press reset
button and repeat step #3, if continuity is not present
as described, replace the circuit breaker.
SERVICE (cont.)
FIG. 6 CIRCUIT BREAKERS
P2214
FIG. 7 CIRCUIT BREAKER TERMINALS
P1330
BLU/BLK to Transformer #12
BLU/BLK to Rectifier "AC"
32248 100500
Removal and Replacement:
1. Remove the wires from the circuit breaker.
2. Compress the clips on the back side of the server
platform and gently push the circuit breaker through
the opening in the server platform.
3. Push the new circuit breaker into the opening in
the server platform until the clips snap into posi-
tion.
4. Reconnect the wires to the circuit breaker.
5. Refer to Fig. 7 when reconnecting the wires.