TallyGenicom la650 ユーザーガイド

ページ / 144
User guide
The Menu
52
Data format (Format)
This parameter serves to define the number of data bits, the parity 
check for received data bytes and the number of stop bits per data 
byte.
Press Format (3) key.
Use the 
<
 (2) or 
>
 (3) key to select the desired setting.
Setting Options: see table below
Default Setting: 8 Bit No 1 Stop
1 Sets the number of data bits: You can select 7 or 8.
2 The parity test for received data bytes can be selected. NO cau-
ses transmission in both directions without parity bit. If EVEN or 
ODD is selected, the bytes are checked if they have even or odd 
parity. The selection of MARK or SPACE causes a data byte 
transmission with parity bit, but without checking the received da-
ta. Transmission data with parity bit is always marked with 1 
(MARK) or 0 (SPACE).
3 Selects one or two stop bits per data byte.
Confirm the setting by pressing the Set key (1). Press the Next key 
(4) to access the next group of parameters.
Baud Format
Online
Setup
2
1
3
4
Back
Next
8bit No
1Stop*
Online
Setup
Set
<
>
Exit
2
1
3
4
1 number of data bits
2 parity test
3 number of stop bits
8 Bit
No
1 Stop
8 Bit
No
2 Stop
8 Bit
Even
1 Stop
8 Bit
Odd
1 Stop
8 Bit
Mark
1 Stop
8 Bit
Spc
1 Stop
7 Bit
No
 2 Stop
7 Bit
Even
1 Stop
7 Bit
Odd
1 Stop
7 Bit
Even
2 Stop
7 Bit
Odd
2 Stop
7 Bit
Mark
1 Stop
7 Bit
Spc
1 Stop
7 Bit
Mark
2 Stop
7 Bit
Spc
 2 Stop