Star Micronics TUP900 インストール手順

ページ / 8
Assembly – Paper Roll Setup 
 
It is necessary to adjust the paper roll holder for the width of the paper you use. If the setting position is incorrect, the 
paper roll will be supplied improperly to the mechanism which in turn causes paper transport problems. Thus, it is should 
be properly adjusted. 
 
The following table shows the paper roll 
holder and paper core inner diameter range. 
 
Paper roll Holder 
Types 
Paper Core 
Diameter Ranges 
Paper roll Holder (1) 
25.4 mm ± 1 
Paper roll Holder (2) 
50.8 mm ± 1 
Paper roll Holder (3) 
76.2 mm ± 1 
 
Note 1) The unit is assembled for 1 inch paper 
cores when shipped from the factory. Also, it is set 
for a paper width of 111.5 ±0.5 (take-up width of 
112 +0.5/-1) when the printer is shipped from the 
factory. 
 
Roll Holder Size 
Paper Thickness 
1” or 25.4 mm 
65 to 100 µm 
2” or 50.8 mm 
100 to 150 µm 
3” or 76.2 mm 
100 to 150 µm 
 
 
8.3 A
 is a reference for the paper roll holder unit paper roll shaft position. Adjust or mount the paper roll holder unit for 
the core diameter and width of the paper you intend to use. 
 
8-3-1 Handling 111.5 mm Paper Width 
See Fig. 8.3.1 for the paper roll holder setting position to handle paper widths of 111.5 ±0.5 mm. 
Position the edge of the paper roll holder onto the central position of the references a and a'. 
 
See the figure to assembly at the correct position. 
 
Note 1) The paper roll holder is assembled to that position when shipped from the factory. 
 
8-3-2 Handling 82 mm Paper Width
 
See Fig. 8.3.2 for the paper roll holder setting position to handle paper widths of 82 ±0.5 mm. 
Position the edge of the paper roll holder onto the central position of the references c and c'. 
See the figure to assembly at the correct position. 
 
Note 1) In this case, be careful because the edge of the paper roll holder positioned on the reference is the opposite. 
 
8-3-3 Handling 79.5 mm Paper Width 
See Fig. 8.3.3 for the paper roll holder setting position to handle paper widths of 79.5 ±0.5 mm. 
Position the edge of the paper roll holder onto the central position of the references b and b'. 
See the figure to assembly at the correct position. 
Starski says, “The size of 
the core used is related 
to the thickness of the 
paper used.”