KYOCERA km-1500 ユーザーガイド

ページ / 408
PRESCRIBE Command Reference
374
XBCP 12 — 
enable time stamp
Format 
XBCP 12, 
time;
Parameter 
time: 
total number of seconds since 00:00:00 AM January 1, 1970 Greenwich mean time
Function 
A Macro PDF417 symbol contains an optional time stamp field. The XBCP 12 command 
enables this function. The execution of this command also automatically sets Macro 
PDF417 symbol mode.
File 
To set time stamp at 06:15:30AM on Jan. 2, 1970:
!R! RES;
XBCP 12, 108930; 
MZP 1,0; XBCP 18,0;
XBAR; ...
... 
EXIT;