Avocent PM10-20A ATP3020-001 ユーザーズマニュアル

製品コード
ATP3020-001
ページ / 4
Quick Facts
•  Power control over remote IT 
assets from anywhere on earth
•  Seamless integration with 
other Avocent appliances 
and with the DSView™ 3 
management software 
•  Proactive fault management 
and isolation
•  Fault notifications via e-mail, 
SMS page and SNMP traps
Benefits
•  Restore practically any IT asset 
without dispatching service 
personnel
•  Virtually eliminate power 
control errors during crisis 
situations
•  Improve administrative 
efficiency with integrated 
control functions
•  Proactively identify and 
manage problems to improve 
mean time between failure 
(MTBF)
•   Reduce risk, reduce mean 
time to repair (MTTR)
•  Conserve valuable IP 
addresses and switch ports
Integrated Remote Power Management and Distribution  
for Use in Branch and Remote Offices 
Avocent PM PDUs enable remote power control and system management of IT assets in 
branch and remote offices. When used in conjunction with Avocent ACS advanced console 
servers, MergePoint Unity™ KVM over IP and serial console switches or DSR™ KVM over IP 
switch appliances, the Avocent PM PDUs offer quick problem resolution through an integrated 
management interface. With one or more outlets positively associated with a particular device, 
users may control power “in line” through a user-defined “hot key” or by using an intuitive Web 
browser-based graphical user interface (GUI). In addition, a special command set facilitates 
scripting.
NEMA Models 
Avocent NEMA PM PDU models are equipped with 5-15R power outlets and fixed power cables. 
These units are available in 15A, 20A and 30A capacities with optional twist-lock input plugs. 
Each model includes two RS-232 ports: one for management and the second for daisy-chain 
expansion. Daisy chaining allows an operator to control up to 128 power outlets as a single 
device. The NEMA models are designed to operate in 100-125 VAC environments. 
IEC Models 
Avocent IEC PM PDU models are equipped with IEC320-C13 power outlets and either IEC320 
modular inlets or fixed power cables. These units are available in 10A, 15A, 16A, 20A, 30A and 
32A capacities. Each model includes two RS-232 ports: one for management and the second 
for daisy-chain expansion. Daisy chaining allows an operator to control up to 128 power outlets 
as a single device. The IEC models are designed to operate in 100-240 VAC environments.
An LED display shows the real-time, true RMS current draw. Each PM PDU may be configured 
to sound an alarm during an overcurrent condition, and if it is connected to an Avocent ACS 
console server, the PDU may also send notifications via e-mail messages, Short Message Service 
(SMS) pager messages and SNMP traps.
Infrastructure Management &  
Monitoring for
Business-Critical Continuity
TM
Avocent
®
 Power Management 10/20 Series 
Distribution Units (PM 10/20 PDUs)
Avocent PM 10 Horizontal PDU